2CSR255164R1164 ABB DS301CT C16 A30 16 A 30 mA Type A 6 kA RCBO

2CSR255164R1164 ABB DS301CT C16 A30 16 A 30 mA Type A 6 kA RCBO

ABB DS301CT C16 A30 is a compact traction-focused 1P+N Type A RCBO with a 16 A C-curve rating, 30 mA residual current sensitivity and 6 kA breaking capacity for overload, short-circuit and earth leakage protection.

SKU: 2CSR255164R1164Alt SKU: DS301CTC16A30MPN: 2CSR255164R1164
Price
List Price £159.28 ex VAT
Your Price (ex VAT) Save 25%
£119.46 25% OFF
You save £39.82 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £119.46
Trade pricing is personalised to your account

Manufacturer Lead Time

£119.46

Why Choose the ABB DS301CT C16 A30 RCBO?

The ABB DS301CT C16 A30 is a compact 1P+N residual current circuit breaker with overcurrent protection (RCBO) developed for traction applications and designed to protect single-phase circuits against overloads, short circuits and earth leakage faults. Combining overcurrent and residual current protection within one device provides dedicated circuit protection in a space-efficient modular format.

This RCBO has a rated current of 16 A, a C-curve tripping characteristic and a rated residual operating current of 30 mA. Its Type A residual current characteristic responds to sinusoidal AC and pulsating DC residual currents, while its 6 kA breaking capacity provides short-circuit protection for appropriately designed circuits.

The DS301CT range is specifically intended for traction applications and meets the R22, R23 and R26/HL3 hazard-level requirements of EN 45545-2. The DS301CT C16 A30 combines these traction-focused characteristics with a compact 1P+N configuration, a weight of approximately 0.1 kg and coordinated protection suitable for demanding electrical distribution environments.

Key Advantages

  • Combined residual current, overload and short-circuit protection within one compact RCBO.
  • 16 A C-curve characteristic suitable for appropriate circuits with moderate starting or inrush currents.
  • 30 mA residual current sensitivity for additional protection against electric shock.
  • Type A residual current protection for sinusoidal AC and pulsating DC residual currents.
  • 6 kA breaking capacity for dependable short-circuit protection.
  • Specifically designed for traction applications.
  • Meets R22, R23 and R26/HL3 requirements under EN 45545-2.
  • Compact 1P+N construction helps optimise available installation space.

Key Features

  • ABB DS301CT RCBO series.
  • 16 A rated current.
  • C tripping characteristic.
  • Type A residual current protection.
  • 30 mA rated residual operating current.
  • 6 kA rated short-circuit breaking capacity.
  • 1P+N configuration.
  • Protection against sinusoidal AC and pulsating DC earth fault currents.
  • Protection against overload and short-circuit currents.
  • Designed specifically for traction electrical applications.
  • EN 45545-2 compliant for relevant R22, R23 and R26/HL3 requirements.
  • Approximate unit weight of 0.1 kg.

Type A Protection for Traction Applications

The ABB DS301CT C16 A30 combines residual current protection with overload and short-circuit protection within a single RCBO. Its Type A residual current characteristic provides protection against the effects of sinusoidal alternating and direct pulsating earth fault currents. With a rated residual current of 30 mA, it also provides additional protection against direct contact when correctly selected and installed.

The C-curve characteristic makes the device suitable for appropriate circuits that can experience moderate starting or inrush currents, while its 16 A rating and 6 kA breaking capacity provide coordinated overcurrent protection. The DS301CT series is specifically designed for traction environments and meets relevant EN 45545-2 fire behaviour requirements for R22, R23 and R26 at hazard level HL3.

Typical Applications

  • Traction electrical distribution systems.
  • Railway and rolling-stock electrical applications.
  • Suitable single-phase traction circuits.
  • Circuits requiring 16 A C-curve overcurrent protection.
  • Circuits requiring 30 mA Type A residual current protection.
  • Circuits exposed to sinusoidal AC or pulsating DC residual currents.
  • Applications requiring compliance with relevant EN 45545-2 hazard-level requirements.
  • Space-conscious electrical assemblies requiring combined RCBO protection.

Technical Specifications

Series DS301CT
ABB order code 2CSR255164R1164
Product group DS300 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N
Rated current 16 A
Tripping characteristic C curve
Residual current type Type A
Rated residual current 30 mA
Rated short-circuit breaking capacity 6 kA
Residual current detection Sinusoidal AC and pulsating DC residual currents
Application Traction
Hazard level R22, R23 and R26/HL3
Unit weight approx. 0.1 kg
Pack unit 1 piece
Standards IEC 61009-1, IEC 61009-2-1, EN 45545-2:2013+A1:2015

Frequently Asked Questions

What is the ABB DS301CT C16 A30 used for?

The ABB DS301CT C16 A30 is a 1P+N Type A RCBO designed specifically for traction applications, providing protection against overloads, short circuits and residual earth leakage currents.

What is the current rating and trip curve of the DS301CT C16 A30?

The DS301CT C16 A30 has a rated current of 16 A and a C-curve tripping characteristic, making it suitable for appropriate circuits that can experience moderate starting or inrush currents.

What residual current protection does the DS301CT C16 A30 provide?

The device provides Type A residual current protection with a rated residual operating current of 30 mA, responding to sinusoidal AC and pulsating DC residual currents.

What is the breaking capacity of the ABB DS301CT C16 A30?

The ABB DS301CT C16 A30 has a rated short-circuit breaking capacity of 6 kA.

What is the ABB order code for the DS301CT C16 A30?

The ABB order code for the DS301CT C16 A30 is 2CSR255164R1164.

Trusted ABB Traction Circuit Protection

ABB DS301CT RCBOs combine overload, short-circuit and Type A residual current protection in a compact 1P+N format specifically designed for traction applications, with compliance to relevant IEC and EN 45545-2 requirements.