2CSR255164R1105 ABB DS301CT B10 A30 RCBO 1P+N Type A 30mA 10A 6kA Traction

2CSR255164R1105 ABB DS301CT B10 A30 RCBO 1P+N Type A 30mA 10A 6kA Traction

ABB DS301CT B10 A30 is a compact traction-rated 10 A 1P+N Type A RCBO with B-curve overcurrent protection, 30 mA residual-current sensitivity, 6 kA short-circuit breaking capacity and railway-specific fire, smoke, shock and vibration performance.

SKU: 2CSR255164R1105Alt SKU: DS301CTB10A30MPN: 2CSR255164R1105
Price
List Price £175.40 ex VAT
Your Price (ex VAT) Save 25%
£131.55 25% OFF
You save £43.85 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £131.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£131.55

Why Choose the ABB DS301CT B10 A30 RCBO?

The ABB DS301CT B10 A30 is a compact 1P+N residual current circuit breaker with overcurrent protection (RCBO) specifically designed for traction and railway applications. Part of the ABB DS301C T traction range, it combines overload, short-circuit and residual-current protection within a single-module device, providing comprehensive protection where installation space is at a premium.

This RCBO provides Type A residual-current protection, responding to sinusoidal alternating and pulsating DC residual currents. Its 30 mA rated residual operating current provides additional protection against direct contact as well as earth-fault protection, while the DS301CT design is engineered for the demanding environmental requirements associated with railway rolling stock.

With a rated current of 10 A, B tripping characteristic and 6 kA rated short-circuit breaking capacity, the DS301CT B10 A30 is suitable for traction circuits with relatively low starting and inrush currents. The range meets EN 45545-2 R22, R23 and R26/HL3 fire and smoke requirements and IEC 61373 Category 1 Class B shock and vibration requirements for railway applications.

Key Advantages

  • Purpose-designed RCBO for traction and railway rolling-stock applications.
  • Combines residual-current, overload and short-circuit protection in one compact device.
  • 10 A rated current with B-curve overcurrent protection.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type A protection responds to sinusoidal AC and pulsating DC residual currents.
  • 6 kA short-circuit breaking capacity.
  • Railway-qualified for demanding fire, smoke, shock and vibration environments.

Key Features

  • ABB DS301C T traction RCBO series.
  • 10 A rated current.
  • B tripping characteristic.
  • Type A residual-current protection.
  • 30 mA rated residual operating current.
  • 6 kA rated short-circuit breaking capacity.
  • 1P+N configuration with one protected pole and two-pole switching.
  • Designed specifically for traction and rolling-stock installations.
  • EN 45545-2 HL3 fire and smoke performance.
  • IEC 61373 Category 1 Class B shock and vibration resistance.
  • Compact one-module format.

Compact Type A Protection for Railway and Traction Circuits

The ABB DS301CT B10 A30 combines miniature circuit breaker and residual-current protection functions within one compact RCBO. It protects single-phase circuits against overload and short-circuit currents while also responding to sinusoidal alternating and pulsating DC residual earth fault currents. The 30 mA sensitivity provides additional protection against direct contact, while the B-curve characteristic is suitable for loads with relatively low starting currents.

The DS301C T series is specifically engineered for traction environments rather than conventional building installations alone. Compliance with EN 45545-2 R22, R23 and R26 at hazard level HL3 supports demanding railway fire and smoke requirements, while IEC 61373 Category 1 Class B qualification addresses the shock and vibration conditions encountered in rolling-stock applications.

Typical Applications

  • Railway rolling-stock electrical systems.
  • Train and rail-vehicle auxiliary circuits.
  • Traction electrical distribution panels.
  • On-board lighting and control circuits.
  • Single-phase railway circuits requiring Type A residual-current protection.
  • Space-constrained rolling-stock modular protection assemblies.

Technical Specifications

Series DS301C T
SKU DS301CTB10A30
ABB order code 2CSR255164R1105
GTIN / EAN 8012542362654
Product type Traction residual current circuit breaker with overcurrent protection (RCBO)
Rated current 10 A
Tripping characteristic B curve
Residual-current type Type A
Rated residual operating current 30 mA
Rated short-circuit breaking capacity 6 kA
Number of poles 1P+N
Protected poles 1
Switching 2-pole
Rated voltage 240 V AC
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Railway fire and smoke standard EN 45545-2
EN 45545-2 classification R22, R23 and R26/HL3
Shock and vibration classification IEC 61373 Category 1 Class B
Module width 1 module
Application Traction and railway rolling stock
Product weight approx. 0.109 kg
Average power loss approx. 0.480 W

Frequently Asked Questions

What is the ABB DS301CT B10 A30 designed for?

The DS301CT B10 A30 is specifically designed for traction and railway rolling-stock applications, providing combined overload, short-circuit and Type A residual-current protection for single-phase circuits.

What is the rated current and breaking capacity of this RCBO?

The ABB DS301CT B10 A30 has a rated current of 10 A, a B-curve tripping characteristic and a rated short-circuit breaking capacity of 6 kA.

What does Type A residual-current protection mean?

Type A means the RCBO responds to sinusoidal alternating residual currents and pulsating DC residual currents, making it suitable for circuits containing many types of modern electrical and electronic equipment.

What residual-current sensitivity does the DS301CT B10 A30 provide?

The RCBO has a rated residual operating current of 30 mA, providing residual earth-fault protection and additional protection against direct contact.

What railway requirements does the DS301CT B10 A30 meet?

The DS301C T range meets EN 45545-2 R22, R23 and R26/HL3 fire and smoke requirements and IEC 61373 Category 1 Class B requirements for shock and vibration resistance in railway applications.

Trusted ABB Traction Circuit Protection

ABB DS301C T RCBOs combine compact overload, short-circuit and residual-current protection with railway-specific fire, smoke, shock and vibration performance, providing a space-efficient solution for demanding traction and rolling-stock electrical systems.