2CSR255163R1135 ABB DS301C B13 A30 13 A 30 mA Type A 6 kA RCBO

2CSR255163R1135 ABB DS301C B13 A30 13 A 30 mA Type A 6 kA RCBO

ABB DS301C B13 A30 is a compact voltage-independent 1P+N Type A RCBO with a 13 A B-curve rating, 30 mA residual current sensitivity and 6 kA breaking capacity for overload, short-circuit and earth leakage protection.

SKU: 2CSR255163R1135Alt SKU: DS301CB13A30MPN: 2CSR255163R1135
Price
List Price £152.62 ex VAT
Your Price (ex VAT) Save 25%
£114.47 25% OFF
You save £38.16 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £114.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£114.47

Why Choose the ABB DS301C B13 A30 RCBO?

The ABB DS301C B13 A30 is a compact 1P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase final circuits against overloads, short circuits and earth leakage faults. Combining these protective functions within a single-module device helps maximise available space inside electrical distribution boards while providing dedicated protection for individual circuits.

This RCBO has a rated current of 13 A, a B-curve tripping characteristic and a rated residual operating current of 30 mA. Its Type A residual current characteristic detects sinusoidal AC and pulsating DC residual currents, while its 6 kA breaking capacity provides short-circuit protection for appropriately designed installations.

The DS301C B13 A30 operates at a rated voltage of 230–240 V AC at 50 Hz and uses voltage-independent residual current protection. Contact position and earth fault indication assist with device status identification, while terminals accept conductors up to 16 mm² and compatible busbars up to 10 mm².

Key Advantages

  • Combined residual current, overload and short-circuit protection within one compact RCBO.
  • 13 A B-curve characteristic suitable for appropriate circuits with relatively low starting or inrush currents.
  • 30 mA residual current sensitivity for additional protection against electric shock.
  • Type A residual current protection for sinusoidal AC and pulsating DC residual currents.
  • 6 kA breaking capacity for dependable short-circuit protection.
  • Voltage-independent residual current operation.
  • Single-module 1P+N construction helps conserve distribution board space.
  • Contact position and earth fault indicators support straightforward status identification.

Key Features

  • ABB DS301C RCBO series.
  • 13 A rated current.
  • B tripping characteristic.
  • Type A residual current protection.
  • 30 mA rated residual operating current.
  • 6 kA rated short-circuit breaking capacity.
  • 1P+N configuration.
  • 230–240 V AC rated voltage.
  • 50 Hz rated frequency.
  • Voltage-independent residual current protection.
  • Contact position indication.
  • Earth fault indication.
  • Compact single-module construction.
  • DIN-rail mounting for modular distribution boards.

Reliable Type A Circuit Protection

The ABB DS301C B13 A30 combines overcurrent and residual current protection within one compact protective device. It protects its connected circuit against overload and short-circuit currents while its Type A residual current function responds to sinusoidal AC and pulsating DC earth leakage currents. The 30 mA sensitivity also provides additional protection against direct contact when correctly selected and installed as part of an appropriate electrical system.

Its B-curve characteristic is suitable for appropriate circuits with relatively low normal starting currents, while the voltage-independent residual current function does not depend on an external power source for operation. Combined with a 6 kA breaking capacity and compact single-module construction, the DS301C B13 A30 provides a practical protection solution where both performance and distribution board space are important.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial electrical installations.
  • Building services distribution systems.
  • Suitable single-phase final circuits.
  • Circuits requiring 13 A B-curve overcurrent protection.
  • Circuits requiring 30 mA Type A residual current protection.
  • Circuits supplying suitable modern electrical and electronic equipment.
  • Space-constrained distribution boards requiring single-module RCBO protection.

Technical Specifications

Series DS301C
ABB order code 2CSR255163R1135
Product group DS300 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N
Rated current 13 A
Tripping characteristic B curve
Residual current type Type A
Rated residual current 30 mA
Rated short-circuit breaking capacity 6 kA
Rated voltage 230–240 V AC
Rated frequency 50 Hz
Operating principle Voltage independent
Module width 1 module
Contact position indicator Yes
Earth fault indicator Yes
Maximum conductor cross-section 16 mm²
Maximum busbar cross-section 10 mm²
Terminal tightening torque 1.2 Nm
Weight approx. 0.1 kg
EAN 8012542359654

Frequently Asked Questions

What is the ABB DS301C B13 A30 used for?

The ABB DS301C B13 A30 is a compact 1P+N RCBO designed to protect suitable single-phase final circuits against overloads, short circuits and residual earth leakage currents.

What is the current rating and trip curve of the DS301C B13 A30?

The DS301C B13 A30 has a rated current of 13 A and a B-curve tripping characteristic, making it suitable for appropriate circuits with relatively low normal starting or inrush currents.

What residual current protection does the DS301C B13 A30 provide?

The device provides Type A residual current protection with a rated residual operating current of 30 mA, allowing it to respond to sinusoidal AC and pulsating DC residual currents.

What is the breaking capacity of the ABB DS301C B13 A30?

The ABB DS301C B13 A30 has a rated short-circuit breaking capacity of 6 kA.

What is the ABB order code for the DS301C B13 A30?

The ABB order code for the DS301C B13 A30 is 2CSR255163R1135.

Trusted ABB Circuit Protection

ABB DS301C RCBOs combine overload, short-circuit and residual current protection in a compact single-module format, providing voltage-independent protection and efficient use of space in residential, commercial and building distribution systems.