We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Mersen Surge Protector Type 2 SPD 2 Pole 60 Volt 20KA TNS
MPN: 83020130
Alt. SKU: STPT2-40K75V-2P
Why Choose the Surge Protection Device Type 2 STPT2-40K75V-2P?
Ensure robust protection for single-phase TN-S installations with this Type 2 surge protection device, rated at 40kA Imax (8/20μs) and 75V. Designed for reliable safeguarding against transient overvoltages, it supports 1Ph+N configurations with 2 poles and a pluggable, 2-module format for straightforward installation and maintenance.
Engineered for consistent performance in demanding industrial and commercial environments, this device offers rapid, tool-free replacement and secure system integrity, helping to extend the operational lifespan of sensitive equipment while maintaining compliance with relevant standards.
Technical Specifications
- Item number: 83020130
- Catalogue No: STPT2-40K75V-2P
- Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 75V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules
- EAN/UPC Code: 8435297851110
- RoHS Compliant: Yes
- IEC SPD Type: Class II
- UL SPD Type: Type 2 Component Assembly
- Format: Pluggable
- Nominal Operating Volt Rating (Un): 60
- AC or DC: AC
- Max Discharge Current : Imax (8/20): 40 kA
- Protection Modes: L-PE
- System Configuration: TNS
- Short Circuit Withstand (ISCCR): 25 kA
- Indication System: Yes
- Indication System Type: Green (OK) / Not green (replace)
- Number of Poles: 2-Pole
- Torque Rating: 3 Nm
- Max. Back-Up Fuse: 125 A [gG]
- Housing Material: PA66 CT1
- MOV Response Time: ≤25
- Installation Mounting: DIN rail
- Replacement Plug N-PE: 77707681
- Replacement Plug L-N: 77707681
- Product Width: 36 mm
- Product Length: 70 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.222 kg
- Sell Pack Width: 42 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.192 kg
Product Code: 83020130
Key Benefits
- High surge current capacity of 40kA ensures effective protection against transient overvoltages.
- Pluggable 2-module format allows for easy installation and rapid tool-free replacement.
- Visual indication system with green (OK) and non-green (replace) status for quick diagnostics.
- Compact design (36 mm width) suitable for space-saving DIN rail mounting.
- Complies with IEC Class II and UL Type 2 standards for reliable performance.
- Suitable for single-phase TN-S systems with 2 poles, ensuring system integrity.
Compatibility
This surge protection device is compatible with single-phase TN-S electrical installations requiring Type 2 protection. It is designed for use with systems having nominal operating voltage of 60V AC and supports L-PE protection mode. The device fits standard DIN rail mounting systems and is suitable for integration with backup fuses up to 125 A [gG]. Replacement plugs (N-PE and L-N) are available under part number 77707681.
Applications
- Industrial and commercial electrical distribution boards.
- Protection of sensitive electronic equipment in single-phase TN-S systems.
- Surge protection in manufacturing plants and automation systems.
- Building installations requiring compliance with IEC and UL surge protection standards.
Frequently Asked Questions
What is the maximum surge current this device can handle?
The device can handle a maximum discharge current (Imax) of 40 kA (8/20μs waveform).
Can this SPD be used in three-phase systems?
No, this device is designed specifically for single-phase TN-S systems with 2 poles.
How do I know when to replace the surge protection device?
The device features a visual indication system: green means the device is operational, while any other colour indicates replacement is needed.
Is the device suitable for DIN rail mounting?
Yes, the device is designed for easy installation on standard DIN rails.
Common Search Terms
Type 2 surge protector, 40kA surge protection device, single-phase SPD, TN-S surge protector, pluggable surge protection, DIN rail SPD, 2-pole surge protector, electrical surge protection device, industrial surge protector, commercial surge protection.
| Manufacturer Part Number | 83020130 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297851110 |
| Height | 70mm |
| Width | 36mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 2 Pole |
| Voltage | 60V |
| Maximum Continuous Voltage | 75V |
| Nominal Discharge Current | 20Ka |
| System Type | TNS |
| Alternative Product SKU | STPT2-40K75V-2P |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.