Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 1+2 SPD 2 Pole 277 Volt 20KA TNS Remote Indication

MPN: 83120123

Alt. SKU: STPT12-12K320V-2PM

Contact us for pricing and availability.
Call us now on 01706 242050

This product is discontinued. Please view this replacement item.
44120213

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 1+2 STPT12-12K320V-2PM?

Engineered for reliable protection, this Type 1+2 SPD safeguards single-phase + neutral (1Ph+N) systems up to 277V in TNS configurations. Delivering a robust 12.5kA Iimp (10/350) impulse current handling per pole, it effectively shields critical equipment from lightning strikes and transient overvoltages.

Featuring two pluggable modules and remote status indication, this 2-pole surge protector streamlines maintenance and monitoring. Its compact 2-module DIN rail design ensures straightforward integration into new or existing electrical panels, making it an essential choice for comprehensive system resilience.

Technical Specifications

  • Item number: 83120123
  • Catalogue No: STPT12-12K320V-2PM
  • Description: Surge Protection Device Type 1+2, 12.5kA Iimp (10/350), 1Ph+N, 277/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules, Remote indication
  • EAN/UPC Code: 8435297851448
  • RoHS Compliant: Yes
  • IEC SPD Type: Class I+II
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 277
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 50 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Lightning Impulse Current (10/350) (LIMP): 12.5 kA
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 200 A [gG]
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • Replacement Plug N-PE: 83120003
  • Replacement Plug L-N: 83120003
  • Product Width: 36 mm
  • Product Length: 76 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.31 kg
  • Sell Pack Width: 42 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.28 kg

Product Code: 83120123

Key Benefits

  • High impulse current capacity of 12.5kA per pole for superior surge protection.
  • Pluggable modules allow easy replacement and maintenance without panel disassembly.
  • Remote status indication simplifies monitoring and ensures timely device replacement.
  • Compact 2-module DIN rail design for easy integration into existing electrical panels.
  • Suitable for single-phase + neutral TNS systems up to 277V.

Compatibility

This surge protection device is designed for use in single-phase plus neutral (1Ph+N) TNS electrical systems operating at nominal voltages up to 277V AC. It is compatible with electrical panels that support DIN rail mounting and require Class I+II surge protection. Replacement plugs with catalogue number 83120003 are compatible for both L-N and N-PE connections.

Applications

  • Industrial and commercial electrical distribution boards.
  • Protection of sensitive electronic equipment from transient overvoltages.
  • Lightning protection in buildings with TNS earthing systems.
  • Renewable energy installations requiring surge protection.
  • Data centres and telecommunications infrastructure.

Frequently Asked Questions

What does Type 1+2 surge protection mean?

Type 1+2 surge protection devices combine the features of Type 1 (lightning current handling) and Type 2 (switching surge protection), providing comprehensive protection against both direct lightning strikes and switching surges.

Can this device be used in three-phase systems?

This particular model is designed for single-phase plus neutral (1Ph+N) systems. For three-phase systems, a different SPD model designed for that configuration should be used.

How does the remote status indication work?

The device includes a microswitch that changes state when the SPD requires replacement, enabling remote monitoring systems to receive status updates without manual inspection.

What is the maximum back-up fuse rating for this SPD?

The maximum back-up fuse rating for this device is 200 A [gG], ensuring proper coordination and protection of the SPD.

Common Search Terms

surge protection device, SPD Type 1+2, 12.5kA surge protector, DIN rail SPD, lightning protection, 277V surge protector, pluggable SPD, remote indication SPD, TNS system surge protection, power line SPD

More Information
Manufacturer Part Number 83120123
Packed Quantity 1
Barcode 8435297851448
Height 76mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 277V
Maximum Continuous Voltage 320V
Nominal Discharge Current 20Ka
Remote Indication Yes
System Type TNS
Alternative Product SKU STPT12-12K320V-2PM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 1+2 SPD 2 Pole 277 Volt 20KA TNS Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo