Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TNS Remote Indication

MPN: 83020125

Alt. SKU: STPT2-40K320V-2PM

Contact us for pricing and availability.
Call us now on 01706 242050

This product is discontinued. Please view this replacement item.
44020211

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 277/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules, Remote indication STPT2-40K320V-2PM?

Engineered for reliable surge protection in single-phase TN-S systems, this Type 2 SPD withstands surges up to 40kA (8/20μs), ensuring robust defence for sensitive electrical infrastructure. The pluggable format and compact 2-module width enable straightforward installation and maintenance, optimising system uptime.

Remote indication functionality provides rapid fault notification for enhanced safety and proactive system management. Designed for 277V operation, the unit meets demanding professional requirements in industrial and commercial environments.

Product Code: 83020125

Key Benefits

  • High surge capacity of 40kA (8/20μs) for superior protection
  • Pluggable format allows easy installation and replacement
  • Compact 2-module width saves panel space
  • Remote indication for real-time status monitoring
  • Suitable for single-phase TN-S systems at 277V
  • Robust housing material (PA66 CT1) ensures durability

Compatibility

This surge protection device is compatible with single-phase TN-S electrical systems operating at a nominal voltage of 277V. It is designed to integrate seamlessly with DIN rail mounting setups and supports systems requiring protection for L-PE and N-PE modes. The device is suitable for use with backup fuses up to 125 A [gG].

Applications

  • Industrial and commercial electrical distribution boards
  • Protection of sensitive electronic equipment from transient surges
  • Power line surge protection in single-phase TN-S systems
  • Installation in control panels requiring remote status indication
  • Buildings with high exposure to transient overvoltages

Technical Specifications

  • Item number: 83020125
  • Catalogue No: STPT2-40K320V-2PM
  • Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 277/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules, Remote indication
  • EAN/UPC Code: 8435297851080
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 2 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 277
  • AC or DC: AC
  • Nominal Discharge Current (In) (8/20): 20 kA
  • Max Discharge Current : Imax (8/20): 40 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 125 A [gG]
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • VPR L-G: 1000 V
  • VPR N-G: 1000 V
  • VPR L-N: 2000 V
  • Replacement Plug L1: 83020003
  • Product Width: 36 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.246 kg
  • Sell Pack Width: 42 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.219 kg

Frequently Asked Questions

What is the maximum surge current this SPD can handle?

This device can handle a maximum surge current (Imax) of 40kA (8/20μs).

Is this SPD suitable for three-phase systems?

No, this model is designed specifically for single-phase TN-S systems at 277V.

Does the device provide remote indication?

Yes, it features a remote indication system with a microswitch for fault signalling.

How is the SPD installed?

The SPD is mounted on a DIN rail and features a pluggable format for easy installation and replacement.

Common Search Terms

Surge protection device, Type 2 SPD, 40kA surge protector, 277V surge protector, pluggable SPD, remote indication SPD, single-phase surge protector, DIN rail SPD, power line surge protection, TN-S system SPD

More Information
Manufacturer Part Number 83020125
Packed Quantity 1
Barcode 8435297851080
Height 70mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 277V
Maximum Continuous Voltage 320V
Nominal Discharge Current 20Ka
Remote Indication Yes
System Type TNS
Alternative Product SKU STPT2-40K320V-2PM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TNS Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo