Why Choose the Surge Protection Device Type 1+2 STPT12-12K150V-2P?

This compact, pluggable SPD delivers reliable Type 1+2 protection, designed to withstand impulse currents up to 12.5kA (Iimp, 10/350 μs) for effective safeguarding of single-phase TNS installations. Engineered for 2-pole operation, it supports 120V systems, making it ideal for critical industrial and commercial applications.

Installation is straightforward with a slim, 2-module DIN-rail design, while replaceable cartridges ensure fast maintenance. Count on STPT12-12K150V-2P for robust protection against transient overvoltages, minimising downtime and enhancing equipment longevity.

Product Code: 83120118

Key Benefits

  • Reliable Type 1+2 surge protection for enhanced safety.
  • High impulse current capacity of 12.5kA (10/350 µs) for robust defence.
  • Compact 2-module DIN-rail mount design saves installation space.
  • Replaceable cartridges for quick and easy maintenance.
  • Clear green indication system for operational status monitoring.
  • Suitable for single-phase TNS systems at 120V.

Compatibility

The STPT12-12K150V-2P is compatible with single-phase TNS electrical systems operating at 120V. It is designed for use in industrial and commercial environments requiring Type 1+2 surge protection and fits standard DIN rails for easy integration into existing switchgear.

Applications

  • Industrial control panels and machinery protection.
  • Commercial building electrical distribution boards.
  • Critical infrastructure requiring transient overvoltage protection.
  • Renewable energy systems with TNS configuration.
  • Any installation needing compact, pluggable surge protection.

Technical Specifications

  • Item number: 83120118
  • Catalogue No: STPT12-12K150V-2P
  • Description: Surge Protection Device Type 1+2, 12.5kA Iimp (10/350), 1Ph+N, 120/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules
  • EAN/UPC Code: 8435297851400
  • RoHS Compliant: Yes
  • IEC SPD Type: Class I+II
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 120
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 50 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Lightning Impulse Current (10/350) (LIMP): 12.5 kA
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace)
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 200 A [gG]
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • Replacement Plug N-PE: 83120001
  • Replacement Plug L-N: 83120001
  • Product Width: 36 mm
  • Product Length: 76 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.26 kg
  • Sell Pack Width: 43 mm
  • Sell Pack Length: 105 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.24 kg

Frequently Asked Questions

What types of systems is this SPD suitable for?

This SPD is designed for single-phase TNS systems operating at 120V, commonly found in industrial and commercial installations.

How does the indication system work?

The device features a green indicator to show operational status. If the indicator is not green, it signals that the cartridge needs replacement.

Can the cartridges be replaced on-site?

Yes, the STPT12-12K150V-2P has pluggable and replaceable cartridges for quick maintenance without removing the entire unit.

What is the maximum back-up fuse rating?

The maximum back-up fuse rating for this device is 200 A [gG].

Common Search Terms

surge protection device, SPD Type 1+2, 12.5kA surge protector, 120V SPD, pluggable surge protector, DIN rail SPD, industrial surge protection, TNS system SPD, transient overvoltage protection

More Information
Manufacturer Part Number 83120118
Packed Quantity 1
Barcode 8435297851400
Height 76mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 120V
Maximum Continuous Voltage 150V
Nominal Discharge Current 20Ka
System Type TNS
Alternative Product SKU STPT12-12K150V-2P
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 1+2 SPD 2 Pole 120 Volt 20KA TNS

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo