Mersen Surge Protector Type 2+3 SPD 3 Pole 208 Volt 10KA TNC

MPN: 83230118

Alt. SKU: STPT23-20K150V-3P

Special Price £80.52 £67.10 Regular Price £108.96

Please contact us for a delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph, -/208V, 3+0 TNC, 3 Poles, Pluggable, 3 Modules STPT23-20K150V-3P?

Engineered for reliable three-phase protection, this Type 2+3 SPD delivers robust surge suppression up to 20kA Imax (8/20μs), ensuring the safety of sensitive systems operating at -/208V in a 3+0 TNC configuration. Its pluggable, modular construction streamlines maintenance and minimises downtime, supporting continuous operation in demanding industrial environments.

With three poles across three modules, this device integrates seamlessly into DIN-rail assemblies, offering rapid installation and straightforward replacement. Compliant with international surge protection standards, it is the ideal solution for safeguarding critical infrastructure and maximising equipment lifespan.

Technical Specifications

  • Item number: 83230118
  • Catalogue No: STPT23-20K150V-3P
  • Description: Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph, -/208V, 3+0 TNC, 3 Poles, Pluggable, 3 Modules
  • EAN/UPC Code: 8435297850885
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II + III
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 120/208
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 20 kA
  • Protection Modes: L-PE(N)
  • System Configuration: TNC
  • Combined Discharge Voltage (1,2/50) (Uoc): 10 kV
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace)
  • Number of Poles: 3-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 63 A [gG]
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • Replacement Plug L1: 83230001
  • Product Width: 54 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.31 kg
  • Sell Pack Width: 63 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.283 kg

Product Code: 83230118

Key Benefits

  • High surge current capacity of 20kA ensures robust protection against transient overvoltages.
  • Pluggable modular design allows for quick and easy replacement, reducing maintenance time.
  • Three-pole configuration supports comprehensive three-phase system protection.
  • DIN rail mounting facilitates straightforward installation in industrial panels.
  • Visual indication system provides clear status monitoring for timely maintenance.
  • Complies with IEC Class II + III standards for reliable and certified surge protection.

Compatibility

This surge protection device is compatible with three-phase electrical systems configured in a 3+0 TNC earthing arrangement operating at nominal voltages of 120/208V AC. It integrates seamlessly with DIN rail mounting systems and is suitable for use with backup fuses rated up to 63 A [gG]. Replacement plugs such as model 83230001 ensure continued compatibility and ease of maintenance.

Applications

  • Industrial power distribution panels
  • Commercial building electrical systems
  • Critical infrastructure surge protection
  • Renewable energy installations
  • Data centres and IT equipment protection
  • Manufacturing and process control facilities

Frequently Asked Questions

What is the maximum surge current this device can handle?

The device can handle a maximum discharge current (Imax) of 20kA with an 8/20μs waveform.

Is this SPD suitable for single-phase systems?

No, this particular model is designed for three-phase systems with a 3+0 TNC configuration.

How does the indication system work?

The SPD features a green indicator to show normal operation; if the indicator is not green, it signals that the device needs replacement.

Can this SPD be installed on any DIN rail?

Yes, it is designed for standard DIN rail mounting, making installation straightforward in compatible panels.

Common Search Terms

surge protection device, SPD 20kA, Type 2+3 SPD, three-phase surge protector, pluggable SPD, DIN rail surge protector, 3-pole SPD, TNC system surge protection, industrial surge protector, power line SPD

More Information
Manufacturer Part Number 83230118
Packed Quantity 1
Barcode 8435297850885
Height 70mm
Width 54mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 3 Pole
Voltage 208V
Maximum Continuous Voltage 150V
Nominal Discharge Current 10Ka
System Type TNC
Alternative Product SKU STPT23-20K150V-3P
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2+3 SPD 3 Pole 208 Volt 10KA TNC

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo