Mersen Surge Protector Type 1 SPD 1 Pole 120 Volt 50KA L-N
MPN: 83010103
Alt. SKU: STMT1-50K150V-1P
Why Choose the STMT1-50K150V-1P Surge Protection Device?
The STMT1-50K150V-1P offers robust Type 1 surge protection with a high Iimp rating of 50kA (10/350 µs), ensuring reliable defence against direct lightning strikes and industrial surges on 120V single-phase systems. Its monobloc, 1-pole design in a compact 2-module format allows for straightforward integration into new or existing installations.
Engineered for critical applications, this surge protector delivers fast response and durable performance with precise L-N protection. Choose the STMT1-50K150V-1P to safeguard sensitive equipment and maintain system uptime in demanding electrical environments.
Technical Specifications
- Item number: 83010103
- Catalogue No: STMT1-50K150V-1P
- Description: Surge Protection Device Type 1, 50kA Iimp (10/350), 1Ph, 120V, L-N, 1 Pole, Monobloc, 2 Modules
- EAN/UPC Code: 8435297852322
- RoHS Compliant: Yes
- IEC SPD Type: Class I
- Format: Monobloc
- Nominal Operating Volt Rating (Un): 120
- AC or DC: AC
- Protection Modes: L - N / L-PE / N-PE
- System Configuration: TNS, TNC, TT (only L-N)
- Lightning Impulse Current (10/350) (LIMP): 50 kA
- Following Current (Ifi): 50 kA
- Short Circuit Withstand (ISCCR): 50 kA
- Number of Poles: 1-pole
- Torque Rating: 3 Nm
- MOV Response Time: ≤50
- Installation Mounting: DIN rail
- Product Width: 36 mm
- Product Length: 70 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.282 kg
- Sell Pack Width: 42 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.251 kg
Product Code: 83010103
Key Benefits
- High surge current capacity of 50kA (10/350 µs) for superior protection against lightning and industrial surges.
- Compact monobloc design with 2-module width for easy installation in standard DIN rail systems.
- Fast MOV response time (≤50 ns) ensures immediate protection of sensitive equipment.
- Suitable for multiple system configurations including TNS, TNC, and TT (L-N only).
- Durable construction with a torque rating of 3 Nm for secure mounting and reliable operation.
Compatibility
The STMT1-50K150V-1P is compatible with 120V single-phase AC electrical systems and supports TNS, TNC, and TT system configurations (L-N protection only). Its DIN rail mounting format makes it suitable for integration into most standard electrical distribution boards and panels.
Applications
- Industrial and commercial electrical installations requiring high-level surge protection.
- Protection of sensitive electronic equipment in manufacturing plants and control rooms.
- New installations or retrofitting existing systems with enhanced lightning and surge defence.
- Power distribution panels in critical infrastructure and data centres.
Frequently Asked Questions
What does the 50kA rating mean?
The 50kA rating refers to the Lightning Impulse Current (10/350 µs waveform) capacity the device can safely handle, indicating its ability to protect against high-energy surges such as direct lightning strikes.
Can this device be used in three-phase systems?
This particular model is designed for single-phase (1P) 120V systems. For three-phase systems, a suitable multi-pole SPD should be selected.
How is the device installed?
The STMT1-50K150V-1P is mounted on a standard DIN rail inside the electrical distribution board, allowing for quick and secure installation.
Is the device RoHS compliant?
Yes, this surge protection device complies with RoHS standards, ensuring it is free from hazardous substances.
Common Search Terms
Surge protector 120V, Type 1 SPD, lightning surge arrester, single-phase surge protection, DIN rail SPD, 50kA surge protector, industrial surge device, power line SPD, electrical surge defence.
| Manufacturer Part Number | 83010103 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297852322 |
| Height | 70mm |
| Width | 36mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 1 pole |
| Voltage | 120V |
| Maximum Continuous Voltage | 150V |
| Nominal Discharge Current | 50Ka |
| System Type | L-N |
| Alternative Product SKU | STMT1-50K150V-1P |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.