Mersen Surge Protector Type 1+2 SPD 2 Pole 60 Volt 20KA
MPN: 83120126
Alt. SKU: STPT12-12K75V-2P
Why Choose the STPT12-12K75V-2P Surge Protection Device?
The STPT12-12K75V-2P delivers robust protection against transient overvoltages, combining Type 1+2 performance for effective safeguarding of single-phase TN-S systems. Rated at 12.5kA Iimp (10/350), it is engineered to handle direct lightning strikes and switching surges, ensuring the reliable operation of critical equipment.
This 2-pole, pluggable SPD fits easily into compact enclosures with its 2-module design and features a 60/-V rating for system flexibility. Suited for demanding industrial and commercial environments, it offers swift installation, simple maintenance, and long-term surge resilience.
Product Code: 83120126
Key Benefits
- High surge current rating of 12.5kA (10/350) for superior lightning and surge protection.
- Type 1+2 classification ensures comprehensive protection for critical electrical installations.
- Compact 2-module pluggable design allows easy installation and maintenance.
- Visual indication system for quick status monitoring and replacement alerts.
- Suitable for single-phase TN-S systems with L-PE protection mode.
- Durable PA66 CT1 housing material ensures long-term reliability in industrial environments.
Compatibility
The STPT12-12K75V-2P is compatible with single-phase TN-S electrical systems requiring L-PE protection. It fits standard DIN rail mounting enclosures and supports a maximum back-up fuse rating of 200 A [gG]. Replacement plugs (N-PE and L-N) with catalogue number 83120004 are available for maintenance and upgrades.
Applications
- Industrial power distribution boards
- Commercial building electrical panels
- Renewable energy installations requiring surge protection
- Critical infrastructure and data centres
- Manufacturing plants with sensitive electronic equipment
Technical Specifications
- Item number: 83120126
- Catalogue No: STPT12-12K75V-2P
- Description: Surge Protection Device Type 1+2, 12.5kA Iimp (10/350), 1Ph+N, 60/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules
- EAN/UPC Code: 8435297851264
- RoHS Compliant: Yes
- IEC SPD Type: Class I+II
- Format: Pluggable
- Nominal Operating Volt Rating (Un): 60
- AC or DC: AC
- Max Discharge Current : Imax (8/20): 50 kA
- Protection Modes: L-PE
- System Configuration: TNS
- Lightning Impulse Current (10/350) (LIMP): 12.5 kA
- Indication System: Yes
- Indication System Type: Green (OK) / Not green (replace)
- Number of Poles: 2-Pole
- Torque Rating: 3 Nm
- Max. Back-Up Fuse: 200 A [gG]
- Housing Material: PA66 CT1
- MOV Response Time: ≤25
- Installation Mounting: DIN rail
- Replacement Plug N-PE: 83120004
- Replacement Plug L-N: 83120004
- Product Width: 36 mm
- Product Length: 76 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.345 kg
- Sell Pack Width: 41 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.345 kg
Frequently Asked Questions
What type of electrical systems is this SPD designed for?
The STPT12-12K75V-2P is designed for single-phase TN-S systems with L-PE protection mode.
How does the indication system work?
The device features a visual indicator that shows green when the SPD is functioning correctly and changes colour to indicate when replacement is needed.
Can this SPD handle direct lightning strikes?
Yes, it is rated for 12.5kA lightning impulse current (10/350 µs), making it suitable for direct lightning strike protection.
Is the device easy to install?
Yes, the pluggable 2-module design allows for quick installation on standard DIN rails and easy replacement of plugs.
Common Search Terms
surge protection device, SPD Type 1+2, lightning protection, 12.5kA surge arrester, pluggable SPD, DIN rail SPD, TN-S system surge protector, industrial surge protection, power line SPD, electrical panel surge protection
| Manufacturer Part Number | 83120126 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297851264 |
| Height | 76mm |
| Width | 72mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 2 Pole |
| Voltage | 60V |
| Maximum Continuous Voltage | 75V |
| Nominal Discharge Current | 20Ka |
| Alternative Product SKU | STPT12-12K75V-2P |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.