Why Choose the PSTX142-600-70 [1SFA898110R7000]

The softstarter PSTX142-600-70 has a rated maximum operational current of 142 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.

Technical Specification

  • Function: Three-phase soft start/stop with voltage or torque ramp, built-in bypass, current limit, jog, braking, diagnostics, emergency/fire pump mode.
  • Rated Operational Voltage: 208 to 600 V AC.
  • Rated Operational Current: 142 A inline connection, 245 A inside delta connection.
  • Rated Power: Up to 90 kW inline (500 V), up to 160 kW inside delta (500 V).
  • Control Supply Voltage: 100 to 250 V AC at 50/60 Hz; Control Circuit Voltage 24 V DC.
  • Protection Rating: IP00 for main terminals; Display unit rated IP66, 4x outdoor.
  • Terminal Type: Main circuit bars with 8.5 mm hole diameter; Control circuit rigid conductor up to 2.5 mm².
  • Tightening Torque: 14 N·m for main circuit connections.
  • Communication: Modbus RTU/TCP, Ethernet-IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP/MSTP.

Trusted By Customers Worldwide

"Specified by UK panel builders for dependable control." Controls Engineer, UK

Frequently Asked Questions

What is the maximum operational current of the PSTX142-600-70?
The maximum operational current is 142 A for inline connection and 245 A for inside delta connection.
What voltage range does the PSTX142-600-70 operate within?
The operating voltage range is from 208 to 600 V AC.
What types of motors is the PSTX suitable for?
The PSTX is suitable for medium to large-sized three-phase motors with nominal currents from 30 to 1250 A inline or 52 to 2160 A inside delta.
What communication protocols are supported by the PSTX?
The PSTX supports Modbus RTU/TCP, Ethernet-IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, and BACnet-IP/MSTP.
What is the protection rating of the display unit?
The display unit has a protection rating of IP66 and is rated for outdoor use (4x outdoor).
What is the tightening torque for main circuit connections?
The tightening torque for main circuit connections is 14 N·m.
What should I refer to for standards and approvals of the PSTX?
See the manufacturer's data sheet for standards and approvals.
More Information
Manufacturer Part Number 1SFA898110R7000
Barcode 7320500501467
Max Rated Current 143 Amps
Motor Power (kW) at 400V 75Kw
Motor Power (kW) at 500V 90Kw
KW Rating 75kW
HS Code 85371091
Country of Manufacture Sweden
Manufacturer ABB
Alternative Product SKU PSTX142-600-70