Call us now on: 01706 242050 or email [email protected]

ABB af205-40-11-12 110kw/205 amp 48-130v 50/60hz dc contactor

SKU
AF205-40-11-12
Special Price £1,053.00 £877.50 Regular Price £1,655.36

Please contact us for a delivery time

ABB AF205-40-11-12 48-130V50/60HZ-DC Contactor -1SBL527102R1211 4 N.O. main poles

Dimensions
Product Net Width: 140 mm
Product Net Depth: 152,6 mm
Product Net Height: 195,6 mm
Product Net Weight: 3.37 kg

Technical
Number of Main Contacts NO: 4
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 350 A
(1000 V) 40 °C 275 A
(690 V) 70 °C 240 A
(690 V) 60 °C 300 A
(1000 V) 60 °C 250 A
(1000 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie):
(220 / 230 / 240 V) 55 °C 205 A
(415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(380 / 400 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 55 kW
(380 / 400 V) 110 kW
(440 V) 132 kW
(415 V) 110 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 400 A
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 24 ... 60 V
50 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 175 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 130 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 175 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 45 ... 80 ms
Between Coil Energization and NO Contact Closing 25 ... 60 ms
Connecting Capacity Main Circuit:
Rigid Cu-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 2 x 50 ... 120 mm²
Flexible 1 x 6 ... 120 mm²
Connecting Capacity Auxiliary Circuit:
Solid 2 x 1 ... 4 mm²
Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2x0.75 ... 2.5 mm²
Flexible with Ferrule 2 x 0.75 ... 2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars

AF 190-AF370 4-Pole contactors are mainly used for controlling non inductive or slightly inductive loads and for controlling power circuits up to 1000V AC. These contactors are of the block type design with 4 main poles.

More Information
Manufacturer ABB
kW Rating 110KW
Inbuilt Aux 1 N/O, 1 N/C
Alternative Product SKU AF205-40-11-12
Manufacturer Part Number 1SBL527102R1211
Product Lead Time Please contact us for a delivery time
Links Click here for link to ABB website info (opens in new tab)
Write Your Own Review
You're reviewing:ABB af205-40-11-12 110kw/205 amp 48-130v 50/60hz dc contactor

ABB AF Contactor Range

ABB contactor range can be used to control power circuits up to a level of 690 V AC and 220 V DC. The main benefit of ABB's range of AF products are that only a few coils are needed for different control voltages used in many applications without having to change the coil.

These four coil voltages run from between 24...500 V 50/60 Hz or 20...500 V DC. These are AC/DC dual rated which cover a range of amperages rather than set specifications. ABB's AF contactors have built in surge protection and do not require any other surge suppressors.

Accessories are available in the form of front and side mounted auxiliary contact blocks plus being designed as a 1 stack 3 pole block type contactor they can have a one main auxiliary contact. Replacement parts are available as well as other accessories.

You can click on this link to view more ABB information

Latest News

Hello to our newest fans: introducing the Finder 7F range

Hello to our newest fans: introducing the Finder 7F range

April 23, 2024 Read full
5 top benefits of energy monitoring equipment for your business

5 top benefits of energy monitoring equipment for your business

April 16, 2024 Read full
Why choose the Rittal VX25 range for your operations?

Why choose the Rittal VX25 range for your operations?

March 26, 2024 Read full
4 key avenues to help increase efficiency in your operations

4 key avenues to help increase efficiency in your operations

March 21, 2024 Read full