We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
abb softstarter PSR12-600-11 24vac/dc control voltage psr range 12 amp
MPN: 1SFA896106R1100
Alt. SKU: PSR12-600-11
Why Choose the PSR12-600-11 [1SFA896106R1100]
The softstarter PSR12-600-11 has a rated maximum operational current of 12 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specification
- Function: Soft start and stop with voltage ramp control.
- Rated Operational Voltage: 208 ... 600 V AC.
- Rated Operational Current: 12 A.
- Rated Control Voltage: 24 V AC/DC.
- Contact Configuration: RUN signal relay output (Normally Open).
- Protection Rating (IP): IP20 per IEC 60529 and IEC 60947-1.
- Terminal Type and Size Range: Screw terminals; rigid 1/2 x 0.75 ... 2.5 mm².
- Ramp Time Setting: Adjustable 0 to 20 seconds via front potentiometers.
- Maximum Starts per Hour: 10 at 3.5 x Ie (7 sec, 50% duty cycle).
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum operational current of the PSR12-600-11?
What is the operating voltage range for the PSR12-600-11?
Can the PSR12-600-11 be used with a manual motor starter?
What is the rated control voltage for the PSR12-600-11?
How can I adjust the ramp time for starting and stopping?
What is the protection rating of the PSR12-600-11?
What types of motors can the PSR12-600-11 control?
| Manufacturer Part Number | 1SFA896106R1100 |
|---|---|
| Barcode | 7320500477175 |
| Max Rated Current | 12 Amps |
| Motor Power (kW) at 400V | 5.5Kw |
| Motor Power (kW) at 500V | 5.5Kw |
| KW Rating | 5.5kW |
| HS Code | 85371091 |
| Country of Manufacture | China |
| Manufacturer | ABB |
| Alternative Product SKU | PSR12-600-11 |