abb softstarter PSR72-600-11 24vac/dc control voltage psr range 72 amp
MPN: 1SFA896113R1100
Alt. SKU: PSR72-600-11
Why Choose the PSR72-600-11 [1SFA896113R1100]
The softstarter PSR72-600-11 has a rated maximum operational current of 72 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specification
- Function: Soft start and stop with voltage ramp.
- Operational Voltage: 208 to 600 V AC.
- Operational Current: 72 A rated.
- Control Voltage: 24 V AC/DC.
- Run and Bypass Signal Relays: Available, normally open (NO).
- Degree of Protection: IP10 (main terminals).
- Terminal Type and Capacity: Bars; main circuit rigid 1x 6–95 mm² or 2x 6–35 mm².
- Ramp Time: Adjustable 0 to 20 seconds.
- Maximum Starts per Hour: Up to 100 starts.
- Weight: 2.1 kg.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum operational current for the PSR72-600-11?
What is the operational voltage range of the PSR72-600-11?
Can the PSR72-600-11 be used with a manual motor starter?
What is the degree of protection for the PSR72-600-11?
What is the cable capacity for the main circuit terminals?
How many starts per hour can the PSR72-600-11 manage?
What is the control voltage for the PSR72-600-11?
| Manufacturer Part Number | 1SFA896113R1100 |
|---|---|
| Barcode | 7320500477243 |
| Max Rated Current | 72 Amps |
| Motor Power (kW) at 400V | 37Kw |
| Motor Power (kW) at 500V | 45Kw |
| KW Rating | 37kW |
| HS Code | 85371091 |
| Country of Manufacture | China |
| Manufacturer | ABB |
| Alternative Product SKU | PSR72-600-11 |