We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Danfoss 131L9920 VLT HVAC Drive FC-101 90kW Three Phase 380 - 480 VAC IP20
MPN: 131L9920
Alt. SKU: FC-101P90KT4P20H3XXCXXXSXXXXAXBXCXXXXDX
Why Choose the Danfoss FC‑101 HVAC Basic Drive (Part 131L9920)?
The Danfoss FC‑101 (P90K), part number 131L9920, delivers robust 90 kW (125 HP) three‑phase motor control for HVAC, pumps, and compressors. It operates on 380–480 VAC and comes in an IP20 chassis backplate enclosure (Frame H8). This variant includes a built‑in Class A1/B (IEC C1) RFI filter, comes with a coated PCB, and is supplied without brake chopper, local control panel, mains or software options—ideal for OEM chassis-mounted applications.
Technical Specifications
| Part Number | 131L9920 |
|---|---|
| Model Code | FC‑101P90KT4P20H3XXCXXXSXXXXAXBXCXXXXDX |
| Power Rating | 90 kW / 125 HP |
| Voltage | 380–480 VAC, three‑phase |
| Enclosure | IP20 chassis backplate (Frame H8) |
| RFI Filter | Class A1/B (IEC C1) |
| Brake Chopper | Not included |
| Local Control Panel (LCP) | Not included |
| PCB Coating | Coated PCB |
| Net Weight | ≈ 52 kg |
| Gross Weight | ≈ 53.3 kg |
| Frame Size | H8 |
| Certifications | CE, UL/cUL, RoHS; supports UL LZGH2 (A2L refrigerants) |
Frequently Asked Questions
- What EMC/RFI compliance does it provide?
- Does it include a local control panel?
- Is the PCB coated?
- What are typical applications?
Typical Applications
- OEM chassis-mounted systems for HVAC, compressor, or pump control
- Installations using 380–480 VAC with compact backplate mounting
- Where EMC compliance and coated PCB reliability are required without onboard UI
Key Features
- 90 kW / 125 HP at 380–480 VAC
- IP20-rated chassis backplate (Frame H8) for compact OEM integration
- Built‑in Class A1/B (IEC C1) RFI filter—no external EMC device needed for motor cables up to 20 m
- Coated PCB provides enhanced resilience in demanding environments
- No brake chopper or LCP included for simplified design
- Supports both induction and PM motors via V/f or sensorless vector modes
- Includes Fire Mode (Safe Torque Off), Flying Start, and auto‑restart
- Automatic Energy Optimizer delivers ~3–5 % runtime energy savings
| Manufacturer Part Number | 131L9920 |
|---|---|
| Barcode | 5710107089840 |
| Height | 660mm |
| Width | 375mm |
| Depth | 335mm |
| Coating PCB | Coated PCB |
| Control Panel | No Loc. Cont. Panel |
| Filter | (H3) RFI Class A1/B (C1) |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP20 |
| KW Rating | 90kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT HVAC Drive FC-101 |
| Product Image | For Illustration Purposes Only |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-101P90KT4P20H3XXCXXXSXXXXAXBXCXXXXDX |
| Product Lead Time | 7-10 days |