We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
ABB s202m-c4 mcb s200m 2 pole c type 4amp
MPN: 2CDS272001R0044
Alt. SKU: S202M-C4
Why Choose the S202M-C4 [2CDS272001R0044]
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
Technical Specification
- Function: Two tripping mechanisms for overload (thermal delay) and short circuit (electromechanical) protection.
- Voltage Rating: Up to 440 V AC, suitable for 230/400 V AC systems.
- Current Rating: Rated currents up to 63 A.
- Contact Configuration: 2 poles (2P) with red ON/green OFF indication.
- Breaking Capacity: Ultimate short-circuit breaking capacity of 25 kA at 230 V AC, 15 kA at 400/440 V AC.
- Terminal Type and Size Range: Screw terminals; flexible 0.75–25 mm², rigid 0.75–35 mm², busbar 10/10 mm².
- Mechanical and Electrical Endurance: 20,000 cycles each.
- Insulation and Dielectric Rating: Actuator material insulation Group II; dielectric test voltage 2 kV (50/60 Hz, 1 min).
- Tightening Torque: 2.8 N·m for terminals; Pozidriv 2 screwdriver recommended.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What are the tripping mechanisms used in the S200M miniature circuit breakers?
What is the maximum breaking capacity of the S200M circuit breakers?
What are the available configurations for the S200M circuit breakers?
What is the rated current range for the S200M circuit breakers?
What is the suitable cable size for the terminals of the S200M circuit breakers?
What standards do the S200M circuit breakers comply with?
How can auxiliary contacts be mounted on the S200M circuit breakers?
| Manufacturer Part Number | 2CDS272001R0044 |
|---|---|
| Amperage | 4A |
| Number of Poles | 2 Pole |
| Trip Curve Type | Type B 10KA |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S202M-C4 |
| Barcode | 4016779550253 |