We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
ABB s202-z6 mcb s200p 2 pole z type 6a amp
MPN: 2CDS252001R0378
Alt. SKU: S202-Z6
Why Choose the S202-Z6 [2CDS252001R0378]
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical Specification
- Function: Thermal and electromechanical tripping for overload and short circuit protection.
- Voltage Ratings: Up to 480Y/277 V AC and 110 V DC.
- Current Ratings: Rated currents up to 63A (this model 2P configuration).
- Breaking Capacity: Rated ultimate breaking capacity up to 20 kA (230 V AC), service breaking capacity 15 kA (230 V AC).
- Contact Configuration: 2 poles (2P).
- Terminal Type & Size: Screw terminals; compatible with flexible and rigid conductors 0.75–35 mm²; busbar 10/10 mm².
- Mechanical Endurance: 20,000 cycles.
- Electrical Endurance: 20,000 AC cycles.
- Insulation & Dielectric Strength: Insulation group II; dielectric test voltage 2 kV (50/60 Hz, 1 min).
- Contact Position Indication: Red for ON, Green for OFF.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What types of tripping mechanisms are used in the S200 miniature circuit breakers?
What is the maximum breaking capacity of the S200 circuit breakers?
What are the current ratings available for the S200 in a 2P configuration?
What conductor sizes are compatible with the S200 circuit breakers?
Can auxiliary contacts be mounted on the S200 circuit breakers?
What standards do the S200 circuit breakers comply with?
| Manufacturer Part Number | 2CDS252001R0378 |
|---|---|
| Amperage | 6A |
| Number of Poles | 2 Pole |
| Trip Curve Type | Type B 10KA |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S202-Z6 |
| Barcode | 4016779530736 |