We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
SM1RM0016 Lovato magnetic manual motor starter 0.1-0.16 amp
MPN: SM1RM0016
Why Choose the SM1RM0016?
Designed for dependable motor safeguarding, the Lovato SM1RM0016 motor protection circuit breaker delivers high short-circuit performance and precise magnetic trip. With a rated current of 0.16A and an IEC breaking capacity Icu of 100kA at 400V, this unit provides robust protection in demanding panels. A rotary knob ensures straightforward control, while compliance with IEC/EN standards supports reliable integration across industrial control applications.
Engineered for resilience, it features Ui 690 V and Uimp 6 kV, with mechanical life rated at 100000 cycles. Operates from -20 to +60 °C up to 3000 m altitude; terminal tightening torque is 2.5 to 3 Nm and weight is 320 g. Conforms to IEC/EN 60947-1, 60947-2, 60947-4-1, plus UL60947-4-1 and CSA C22.2 n° 60947-4-1.
Key Benefits
- 100kA Icu at 400V for high fault interruption capacity.
- Precise magnetic protection for motor short-circuit events.
- Simple rotary knob control for quick setting and actuation.
- Wide operating temperature range from -20 to +60 °C.
- Long mechanical life rated at 100000 operating cycles.
- High insulation ratings: Ui 690 V and Uimp 6 kV.
- Built to IEC/EN 60947 standards for compliant installations.
- 0.16A rated current for low-current motor protection.
Technical Specification
- Product type designation: SM1RM
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Mechanical life: 100000 cycles
- Terminal tightening torque: 2.5 to 3 Nm
- Operating temperature: -20 to +60 °C
- Storage temperature: -50 to +80 °C
- Max altitude: 3000 m
- Weight: 320 g
What’s Included
- Lovato SM1RM0016 motor protection circuit breaker unit
- Installation and safety information
Applications
- Motor circuits requiring 0.16A protection with magnetic trip
- Panels needing 100kA Icu at 400V short-circuit breaking capacity
- IEC/EN 60947 compliant industrial control assemblies
- Environments from -20 to +60 °C up to 3000 m altitude
Frequently Asked Questions
What is the rated current of the SM1RM0016?
What is the short-circuit breaking capacity at 400V?
Which standards does this breaker conform to?
What are the operating conditions?
Is it UL Type E certified?
Safety note: Installation must be performed by qualified personnel. Isolate power before work and tighten terminals to 2.5–3 Nm, following IEC/EN 60947 guidelines and the manufacturer’s instructions.
| Manufacturer Part Number | SM1RM0016 |
|---|---|
| Barcode | 8013975228005 |
| Manufacturer | Lovato |