SLD 1 Fuse switch disconnector

MPN: 2CGX063050108

Alt. SKU: SLD 1

Special Price £512.71 £427.26 Regular Price £788.80

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the 6305.0108.2 [2CGX063050108]

Fuse switch disconnector with dependent manual operation

Technical Specification

  • Function: Fuse switch disconnector with dependent manual operation.
  • Number of Poles: 3P.
  • Rated Operational Voltage: 400 V.
  • Rated Operational Current: 250 A (AC-22B at 690 V, AC-23B at 400 V).
  • Fuse Type and Size: NH, Size 1.
  • Conventional Thermal Current (Ithe): 250 A.
  • Rated Conditional Short-Circuit Current: 50 kA rms (250 A fuse, 400 V and 690 V).
  • Rated Insulation Voltage (Ui): 690 V.
  • Rated Impulse Withstand Voltage (Uimp): 8 kV.
  • Degree of Protection: IP2X (IEC 60529).
  • Terminal Type and Cable Range: Wire clamp, 50 to 300 mm².
  • Tightening Torque: 15 N·m (terminals), 20 to 35 N·m (wire clamps).

Trusted By Customers Worldwide

"Specified by UK panel builders for dependable control." Controls Engineer, UK

Frequently Asked Questions

What is the function of this product?
This product functions as a fuse switch disconnector with dependent manual operation.
What is the rated operational voltage and current?
The rated operational voltage is 400 V and the rated operational current is 250 A.
What type and size of fuse is compatible with this disconnector?
This disconnector is compatible with NH fuses, Size 1.
What is the cable range for terminal connections?
The terminal type is wire clamp, accommodating cable sizes from 50 to 300 mm².
What is the degree of protection for this product?
The degree of protection is IP2X, according to IEC 60529.
What is the rated conditional short-circuit current?
The rated conditional short-circuit current is 50 kA rms at 400 V and 690 V with a 250 A fuse.
What are the tightening torque specifications for the terminals?
The tightening torque is 15 N·m for terminals and 20 to 35 N·m for wire clamps.
More Information
Manufacturer Part Number 2CGX063050108
Packed Quantity 1
Height 517mm
Width 120mm
Depth 160mm
Manufacturer ABB
Alternative Product SKU SLD 1
Barcode 7331980049127