We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
P1RB1NC10A030 - RCBO 1P+N CURVE C 10A IDN 30MA TYPE A
MPN: P1RB1NC10A030
Why Choose the P1RB1NC10A030?
Lovato’s P1RB1NC10A030 is a residual current circuit breaker with overcurrent protection designed for reliable fault protection. This 2‑module, 1P+N device combines 10kA rating, 10A In, C tripping curve and Type A residual characteristic with 30 mA IΔn to safeguard circuits. Built to IEC/EN 61009‑1, it delivers dependable performance where residual and overcurrent protection must be combined in a single, space‑saving unit.
Engineered for demanding conditions, it offers Ui 400 V and Uimp 4 kV, with IP20 frontal protection. Operating temperature spans −35 to 70 °C (storage −40 to 80 °C), with installation up to 2000 m altitude. Terminals tighten to 1.8–2 Nm, while power dissipation is 1.7 W per pole. The unit weighs 205 g and is rated Pollution degree 2.
Key Benefits
- Residual and overcurrent protection in a compact 2‑module footprint.
- 10kA rated device for robust fault handling.
- Type A, 30 mA residual sensitivity for dependable circuit protection.
- C tripping curve and 10A rated current for consistent operation.
- Rated insulation voltage 400 V; impulse withstand voltage 4 kV.
- IP20 frontal protection with Pollution degree 2 construction.
- Wide operating range −35 to 70 °C; torque 1.8–2 Nm.
Technical Specification
- Rated insulation voltage Ui (IEC/EN): 400 V
- Rated impulse withstand voltage Uimp: 4 kV
- Power dissipation per pole (max): 1.7 W
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 80 °C
- Max altitude: 2000 m
- Terminal tightening torque: 1.8 to 2 Nm
- Weight: 205 g
- IP degree (frontal): IP20
- Pollution degree: 2
What’s Included
- Lovato residual current circuit breaker with overcurrent protection
- Manufacturer datasheet and product documentation
- Standard packaging for transport and storage
Applications
- Circuits requiring combined residual and overcurrent protection in a single device.
- Installations needing 1P+N, 10A, Type A, 30 mA protection.
- Panels specifying 2 DIN‑module devices with C tripping curve.
- Projects requiring IEC/EN 61009‑1 conformity and IP20 frontal protection.
- Environments within −35 to 70 °C and up to 2000 m altitude.
Frequently Asked Questions
What is the rated current and tripping curve?
What residual characteristics does it provide?
How many poles and DIN modules does it have?
What is the device’s fault rating?
What environmental and protection ratings apply?
Safety note: Install and commission only by qualified personnel. Isolate the supply before work, tighten terminals to the specified torque, and follow IEC/EN 61009-1 and local regulations.
| Manufacturer Part Number | P1RB1NC10A030 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975204542 |