Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2 SPD 4 Pole 230/400 Volt 20KA IT Remote Indication

MPN: 83020157

Alt. SKU: STPT2-40K440V-4PM

Contact us for pricing and availability.
Call us now on 01706 242050

This product is discontinued. Please view this replacement item.
44020421

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the STPT2-40K440V-4PM Surge Protection Device?

The STPT2-40K440V-4PM offers robust Type 2 surge protection for three-phase+neutral systems, accommodating both 230/400V and 400/690V configurations, as well as 4+0 IT and TNS earthing arrangements. With a maximum discharge current of 40kA (8/20μs), it reliably safeguards critical equipment from transient overvoltages and lightning-induced surges.

This pluggable, four-pole device is engineered for straightforward installation and maintenance, featuring four modules with remote indication for status monitoring. Its industry-leading protection performance ensures consistent operation and enhanced system resilience in demanding commercial and industrial environments.

Technical Specifications

  • Item number: 83020157
  • Catalogue No: STPT2-40K440V-4PM
  • Description: Surge Protection Device Type 2, 40kA Imax (8/20), 3Ph+N, 230/400; 400/690V, 4+0 IT; TNS, 4 Poles, Pluggable, 4 Modules, Remote indication
  • EAN/UPC Code: 8435297851776
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 2 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 230/400
  • AC or DC: AC
  • Nominal Discharge Current (In) (8/20): 20 kA
  • Max Discharge Current : Imax (8/20): 40 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 4-Pole
  • Torque Rating: 3 Nm
  • Housing Material: PA66 CT1
  • Installation Mounting: DIN rail
  • Uc (L-N): 880 V
  • Uc (L-PE): 440 V
  • VPR L-G: 1500 V
  • VPR L-L: 3000 V
  • VPR N-G: 1500 V
  • VPR L-N: 3000 V
  • Replacement Plug N-PE: 77707655
  • Replacement Plug L-N: 77707655
  • Product Width: 72 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.015 kg
  • Sell Pack Width: 78 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.014 kg

Product Code: STPT2-40K440V-4PM

Key Benefits

  • High surge current capacity with 40kA maximum discharge current for superior protection.
  • Pluggable design allows for quick and easy installation and maintenance.
  • Remote indication feature enables real-time status monitoring for proactive maintenance.
  • Compatible with multiple system configurations including 230/400V and 400/690V, 4+0 IT and TNS.
  • Compact size with DIN rail mounting saves installation space.
  • Robust housing material (PA66 CT1) ensures durability in industrial environments.

Compatibility

The STPT2-40K440V-4PM is compatible with three-phase plus neutral electrical distribution systems operating at 230/400V and 400/690V. It supports 4+0 IT and TNS earthing systems and is suitable for use with DIN rail mounting enclosures. Replacement plugs with catalogue number 77707655 are available for both N-PE and L-N connections.

Applications

  • Industrial electrical distribution boards requiring Type 2 surge protection.
  • Commercial buildings with three-phase power systems.
  • Protection of sensitive electronic equipment from transient voltage surges.
  • Renewable energy installations such as solar PV systems with three-phase configurations.
  • Data centres and critical infrastructure demanding reliable surge protection.

Frequently Asked Questions

What is the maximum discharge current rating of this device?

The STPT2-40K440V-4PM has a maximum discharge current (Imax) rating of 40 kA (8/20 μs waveform).

Can this device be used in both 230/400V and 400/690V systems?

Yes, it is designed to operate effectively in both 230/400V and 400/690V three-phase plus neutral systems.

Does the device provide remote status indication?

Yes, the device features a remote indication system with a green (OK) / not green (replace) microswitch for easy monitoring.

Is the device suitable for DIN rail mounting?

Yes, the STPT2-40K440V-4PM is designed for installation on a standard DIN rail.

Common Search Terms

surge protection device, SPD Type 2, 40kA surge protector, three-phase surge protector, pluggable SPD, DIN rail surge protection, remote indication SPD, industrial surge protection, TNS system SPD, 230/400V surge protector

More Information
Manufacturer Part Number 83020157
Packed Quantity 1
Barcode 8435297851776
Height 70mm
Width 72mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 4 Pole
Voltage 230/400V
Maximum Continuous Voltage 440V
Nominal Discharge Current 20Ka
Remote Indication Yes
System Type IT
Alternative Product SKU STPT2-40K440V-4PM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2 SPD 4 Pole 230/400 Volt 20KA IT Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.