Mersen Surge Protector Type 2 SPD 2 Pole 60 Volt 20KA TNS Remote Indication

MPN: 83020131

Alt. SKU: STPT2-40K75V-2PM

Special Price £92.22 £76.85 Regular Price £122.96

Please contact us for a delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2 STPT2-40K75V-2PM?

This Type 2 Surge Protection Device delivers robust protection for single-phase + neutral (1Ph+N) systems in TNS configurations, featuring 2 poles and supporting a peak discharge current (Imax) of 40kA (8/20μs waveform). Designed for pluggable installation, it occupies only 2 DIN modules, ensuring easy integration in compact panels.

Engineered with built-in remote indication for enhanced monitoring, this SPD safeguards sensitive equipment against transient overvoltages up to 60/-V. The STPT2-40K75V-2PM offers reliable performance and rapid replacement, making it an essential choice for industrial and commercial electrical protection requirements.

Technical Specifications

  • Item number: 83020131
  • Catalogue No: STPT2-40K75V-2PM
  • Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 60/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules, Remote indication
  • EAN/UPC Code: 8435297849384
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 2 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 60
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 40 kA
  • Protection Modes: L-PE
  • System Configuration: TNS
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 125 A [gG]
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • Replacement Plug N-PE: 77707681
  • Replacement Plug L-N: 77707681
  • Product Width: 36 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.228 kg
  • Sell Pack Width: 42 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.196 kg

Product Code: STPT2-40K75V-2PM

Key Benefits

  • High surge current capacity of 40kA (8/20μs) ensures robust protection against transient overvoltages.
  • Compact pluggable design occupies only 2 DIN modules for easy installation in tight panel spaces.
  • Built-in remote indication allows for convenient monitoring of device status.
  • Suitable for single-phase plus neutral (1Ph+N) TNS systems with 2-pole protection.
  • Rapid replacement plugs available for minimal downtime during maintenance.
  • Complies with IEC Class II and UL Type 2 standards for reliable safety performance.

Compatibility

The STPT2-40K75V-2PM is designed for use in AC power distribution systems configured as TNS, supporting single-phase plus neutral wiring. It is compatible with electrical panels that accept DIN rail mounted pluggable devices and can be integrated with backup fuses rated up to 125 A [gG]. Replacement plugs (part no. 77707681) ensure compatibility for both L-N and N-PE connections.

Applications

  • Industrial and commercial electrical distribution boards requiring Type 2 surge protection.
  • Protection of sensitive electronic and electrical equipment in TNS system configurations.
  • Buildings with compact panel space needing pluggable SPD solutions.
  • Systems where remote status indication of surge protection devices is required.
  • Facilities requiring compliance with IEC and UL surge protection standards.

Frequently Asked Questions

What is the maximum surge current this device can handle?

The STPT2-40K75V-2PM can handle a maximum discharge current (Imax) of 40kA (8/20μs waveform).

Is this surge protection device suitable for three-phase systems?

No, this device is designed specifically for single-phase plus neutral (1Ph+N) TNS systems.

How does the remote indication system work?

The device features a microswitch with green (OK) and non-green (replace) status indication, allowing remote monitoring of the SPD condition.

Can I replace the surge protection module without rewiring?

Yes, the pluggable format allows for quick replacement using the designated replacement plugs (part no. 77707681) without rewiring.

Common Search Terms

Type 2 SPD, surge protection device, 40kA surge protector, pluggable SPD, TNS system surge protection, DIN rail SPD, remote indication SPD, industrial surge protector, 2 pole surge device, STPT2-40K75V-2PM

More Information
Manufacturer Part Number 83020131
Packed Quantity 1
Barcode 8435297849384
Height 70mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 60V
Maximum Continuous Voltage 75V
Nominal Discharge Current 20Ka
Remote Indication Yes
System Type TNS
Alternative Product SKU STPT2-40K75V-2PM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2 SPD 2 Pole 60 Volt 20KA TNS Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo