Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TT Remote Indication

MPN: 83020119

Alt. SKU: STPT2-40K320V-2PGM

Contact us for pricing and availability.
Call us now on 01706 242050

This product is discontinued. Please view this replacement item.
44020209

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2, 40kA Imax, 1Ph+N (STPT2-40K320V-2PGM)?

This pluggable, two-pole surge protection device safeguards single phase + neutral (1Ph+N) TT installations, delivering robust protection up to 40kA (8/20μs) and supporting 277V nominal systems. Its compact two-module DIN rail design is ideal for space-limited panels.

Engineered for reliability, it features remote indication for real-time status monitoring and fast maintenance. Suitable for industrial and commercial distribution boards, this SPD delivers high-performance, maintenance-friendly protection against transient overvoltages.

Technical Specifications

  • Item number: 83020119
  • Catalogue No: STPT2-40K320V-2PGM
  • Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 277/-V, 1+1 TT, 2 Poles, Pluggable, 2 Modules, Remote indication
  • EAN/UPC Code: 8435297850762
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 2 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 277
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 40 kA
  • Protection Modes: L-N / N-PE
  • System Configuration: TT, TNS
  • Following Current (Ifi): 100 A
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 125 A [gG]
  • Housing Material: PA66 CT1
  • Installation Mounting: DIN rail
  • Uc (L-N): 320 V
  • Uc (N-PE): 277 V
  • Up at In (N-PE): ≤1,5 kV
  • Up at In (L-N): ≤1,5 kV
  • VPR L-G: 1500 V
  • VPR N-G: 700 V
  • VPR L-N: 1200 V
  • Replacement Plug N-PE: 83020000
  • Replacement Plug L-N: 83020003
  • Product Width: 36 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.233 kg
  • Sell Pack Width: 42 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.202 kg

Product Code: 83020119

Key Benefits

  • High surge current capacity of 40kA (8/20μs) for robust protection
  • Compact two-module DIN rail design saves panel space
  • Remote indication for easy monitoring and maintenance
  • Pluggable format allows quick replacement and installation
  • Suitable for TT and TNS system configurations
  • Reliable protection modes L-N and N-PE ensure comprehensive coverage

Compatibility

This SPD is compatible with single phase plus neutral (1Ph+N) TT and TNS electrical installations operating at nominal voltages up to 277V. It integrates seamlessly with industrial and commercial distribution boards using DIN rail mounting and supports backup fuses up to 125 A [gG]. Replacement plugs 83020000 (N-PE) and 83020003 (L-N) ensure easy maintenance.

Applications

  • Industrial and commercial electrical distribution boards
  • Single phase + neutral TT installations requiring surge protection
  • Buildings with sensitive electronic equipment needing transient overvoltage protection
  • Systems requiring remote indication of SPD status for maintenance
  • Panels with limited space needing compact protection solutions

Frequently Asked Questions

What is the maximum surge current this device can handle?

The device can handle a maximum discharge current (Imax) of 40kA (8/20μs).

Can this SPD be used in TNS systems?

Yes, it is compatible with both TT and TNS system configurations.

Does this device provide remote indication?

Yes, it features a remote indication system with a green (OK) / not green (replace) microswitch.

What is the mounting type for this SPD?

The device is designed for DIN rail mounting.

What are the replacement plug codes for this SPD?

The replacement plug for N-PE is 83020000 and for L-N is 83020003.

Common Search Terms

surge protection device, SPD 40kA, type 2 surge protector, pluggable SPD, DIN rail surge protector, 1Ph+N SPD, TT system surge protection, remote indication SPD, transient overvoltage protection, industrial surge protection

More Information
Manufacturer Part Number 83020119
Packed Quantity 1
Barcode 8435297850762
Height 70mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 277V
Maximum Continuous Voltage 320V
Nominal Discharge Current 20Ka
Remote Indication Yes
System Type TT
Alternative Product SKU STPT2-40K320V-2PGM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TT Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.