Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TNS

MPN: 83020124

Alt. SKU: STPT2-40K320V-2P

Special Price £67.31 £56.09 Regular Price £89.74

Please contact us for a delivery time
Call us now on 01706 242050

This product is discontinued.
Please view this replacement item.
44020210

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2 STPT2-40K320V-2P?

Engineered for robust electrical protection, the STPT2-40K320V-2P offers reliable Type 2 surge protection with a maximum discharge current of 40kA (8/20). This pluggable, two-pole device is ideal for single-phase + neutral (1Ph+N) 277V systems and TNS earthing configurations, ensuring your critical equipment is safeguarded against transient overvoltages.

Designed for ease of installation and maintenance, its compact two-module format fits seamlessly into modern distribution boards. Trusted for both efficiency and compliance, it is the go-to choice for demanding industrial and commercial electrical protection needs.

Product Code: STPT2-40K320V-2P

Key Benefits

  • High surge current capacity with 40kA maximum discharge current (8/20 µs waveform)
  • Compact two-module design for easy integration into distribution boards
  • Pluggable format simplifies installation and replacement
  • Clear indication system ensures quick status checks and maintenance
  • Suitable for 1Ph+N 277V systems with TNS earthing for versatile application
  • Complies with IEC Class II and UL Type 2 standards for assured safety and performance

Compatibility

This surge protection device is compatible with single-phase plus neutral (1Ph+N) 277V AC systems and designed specifically for TNS earthing configurations. It fits standard DIN rail mounting systems and is suitable for use in industrial and commercial electrical distribution boards requiring Type 2 surge protection.

Applications

  • Industrial electrical distribution panels
  • Commercial building power protection
  • Protection of sensitive electronic equipment against transient surges
  • Renewable energy system surge protection
  • Telecommunications and data centres requiring reliable SPD solutions

Technical Specifications

  • Item number: 83020124
  • Catalogue No: STPT2-40K320V-2P
  • Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph+N, 277/-V, 2+0 TNS, 2 Poles, Pluggable, 2 Modules
  • EAN/UPC Code: 8435297851073
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 2 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 277
  • AC or DC: AC
  • Nominal Discharge Current (In) (8/20): 20 kA
  • Max Discharge Current : Imax (8/20): 40 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace)
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Housing Material: PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • VPR L-G: 1000 V
  • VPR N-G: 1000 V
  • VPR L-N: 2000 V
  • Replacement Plug L1: 83020003
  • Product Width: 36 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.244 kg
  • Sell Pack Width: 42 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.214 kg

Frequently Asked Questions

What types of systems is this SPD suitable for?

The STPT2-40K320V-2P is designed for single-phase plus neutral (1Ph+N) 277V AC systems with TNS earthing configuration.

How does the indication system work?

The device features a green indicator when operational (OK). If the indicator is not green, it signals that replacement is necessary.

Can this SPD be installed on a DIN rail?

Yes, the device is designed for easy installation on standard DIN rails.

What is the maximum surge current this device can handle?

The maximum discharge current (Imax) is 40 kA with an 8/20 µs waveform.

Is this product RoHS compliant?

Yes, it complies with RoHS standards ensuring it is free from hazardous substances.

Common Search Terms

Type 2 surge protector, 40kA SPD, pluggable surge protection device, 277V surge protector, TNS system SPD, DIN rail surge protector, industrial surge protection, commercial electrical SPD, two-pole surge protector, transient overvoltage protection.

More Information
Manufacturer Part Number 83020124
Packed Quantity 1
Barcode 8435297851073
Height 70mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 277V
Maximum Continuous Voltage 320V
Nominal Discharge Current 20Ka
System Type TNS
Alternative Product SKU STPT2-40K320V-2P
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2 SPD 2 Pole 277 Volt 20KA TNS

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.