We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Mersen Surge Protector Type 2 SPD 1 Pole 400 Volt 20KA L-N
MPN: 83020110
Alt. SKU: STPT2-40K440V-1P
This product is discontinued.
Please view this replacement item.
Why Choose the Surge Protection Device Type 2, 40kA Imax, 1Ph, 400V, 1 Pole, Pluggable, 1 Module STPT2-40K440V-1P?
This surge protection device is engineered for robust defence against transient overvoltages in single-phase systems, featuring a high discharge capacity of 40kA (8/20µs) to safeguard sensitive electrical and electronic infrastructure. Its 400V L-N rating ensures optimal compatibility with modern low-voltage distribution networks.
The compact, pluggable 1-module design guarantees easy installation, replacement, and enhanced serviceability, minimising downtime. Ideal for industrial and commercial environments requiring reliable Type 2 surge protection conforming to latest safety standards.
Product Code: 83020110
Key Benefits
- High surge current capacity of 40kA ensures superior protection against transient overvoltages.
- Pluggable 1-module design allows for quick installation and easy replacement.
- Compact size (18 mm width) saves space in distribution boards.
- Visual indication system for easy status monitoring (Green = OK, Not green = Replace).
- Compliance with IEC Class II and UL Type 2 standards guarantees reliable performance.
- Suitable for multiple system configurations including TNS, TNC, and TT (L-N only).
Compatibility
This device is compatible with single-phase 400V AC systems and supports protection modes L-N, L-PE, and N-PE. It is designed for use in TNS, TNC, and TT system configurations (only L-N for TT). The device mounts easily on standard DIN rails and is suitable for installations requiring up to 125 A back-up fuse protection.
Applications
- Industrial electrical distribution panels
- Commercial building power systems
- Protection of sensitive electronic equipment from transient surges
- Renewable energy installations requiring surge protection
- Data centres and telecommunications infrastructure
Technical Specifications
- Item number: 83020110
- Catalogue No: STPT2-40K440V-1P
- Description: Surge Protection Device Type 2, 40kA Imax (8/20), 1Ph, 400V, L-N, 1 Pole, Pluggable, 1 Module
- EAN/UPC Code: 8435297850601
- RoHS Compliant: Yes
- IEC SPD Type: Class II
- UL SPD Type: Type 2 Component Assembly
- Format: Pluggable
- Nominal Operating Volt Rating (Un): 400
- AC or DC: AC
- Nominal Discharge Current (In) (8/20): 20 kA
- Max Discharge Current : Imax (8/20): 40 kA
- Protection Modes: L - N / L-PE / N-PE
- System Configuration: TNS, TNC, TT (only L-N)
- Short Circuit Withstand (ISCCR): 25 kA
- Indication System: Yes
- Indication System Type: Green (OK) / Not green (replace)
- Number of Poles: 1-pole
- Torque Rating: 3 Nm
- Max. Back-Up Fuse: 125 A [gG]
- Housing Material: PA66 CT1
- MOV Response Time: ≤25
- Installation Mounting: DIN rail
- VPR L-N: 1500 V
- Replacement Plug L1: 83020004
- Product Width: 18 mm
- Product Length: 70 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.144 kg
- Sell Pack Width: 24 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.126 kg
Frequently Asked Questions
What is the maximum surge current this device can handle?
The device can handle a maximum discharge current (Imax) of 40 kA (8/20 µs waveform).
Can this SPD be used in three-phase systems?
This SPD is designed for single-phase systems only. For three-phase systems, a different model should be selected.
How does the indication system work?
The indication system uses a green indicator to show the device is functioning correctly. If the indicator is not green, the device should be replaced.
Is this device RoHS compliant?
Yes, the device is RoHS compliant, ensuring it meets environmental and safety standards.
Common Search Terms
surge protection device, SPD 40kA, Type 2 surge protector, 400V surge protector, pluggable SPD, single-phase surge protection, DIN rail SPD, power line SPD, transient voltage surge suppressor
| Manufacturer Part Number | 83020110 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297850601 |
| Height | 70mm |
| Width | 18mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 1 pole |
| Voltage | 400V |
| Maximum Continuous Voltage | 440V |
| Nominal Discharge Current | 20Ka |
| System Type | L-N |
| Alternative Product SKU | STPT2-40K440V-1P |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.