Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2+3 SPD 4 Pole 230/400 Volt 10KA TT Remote Indication

MPN: 83230127

Alt. SKU: STPT23-20K275V-4PG-LFM

Special Price £133.58 £111.32 Regular Price £178.10

Please contact us for a delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2+3 STPT23-20K275V-4PG-LFM?

Engineered for robust protection, this Type 2+3 surge protection device offers 20kA Imax (8/20) safeguarding for 3-phase+N TT systems at 230/400V. It is completely leakage current free, ensuring stable operation and maximising system reliability in critical industrial and commercial applications.

The unit features a compact, pluggable 4-pole design with 4 modules and remote indication capability for rapid status checks and straightforward maintenance. Ideal for modern panel installations, it delivers superior surge defence while supporting operational efficiency and compliance.

Technical Specifications

  • Item number: 83230127
  • Catalogue No: STPT23-20K275V-4PG-LFM
  • Description: Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph+N, 230/400V, Leakage current free, 3+1 TT, 4 Poles, Pluggable, 4 Modules, Remote indication
  • EAN/UPC Code: 8435297849414
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II + III
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 230/400
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 20 kA
  • Protection Modes: L-N / N-PE
  • System Configuration: TT, TNS
  • Combined Discharge Voltage (1,2/50) (Uoc): 10 kV
  • Following Current (Ifi): 100 A
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 4-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 63 A [gG]
  • Housing Material: PA66 CT1
  • Installation Mounting: DIN rail
  • Uc (L-N): 275 V
  • Uc (N-PE): 255 V
  • Up at In (N-PE): ≤1,5 kV
  • Up at In (L-N): ≤1,5 kV
  • MCOV L-G: 175 V
  • MCOV L-L: 350 V
  • MCOV N-G: 277 V
  • MCOV L-N: 175 V
  • Replacement Plug N-PE: 83230000
  • Replacement Plug L-N: 83230003
  • Product Width: 72 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.385 kg
  • Sell Pack Width: 78 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.342 kg

Product Code: 83230127

Key Benefits

  • High surge current capacity of 20kA ensures robust protection against transient overvoltages.
  • Leakage current free design enhances system reliability and safety.
  • Compact, pluggable 4-pole modular design simplifies installation and maintenance.
  • Remote indication feature allows quick status monitoring to reduce downtime.
  • Suitable for 3-phase+N TT and TNS systems, providing versatile application options.
  • Compliance with IEC Class II + III standards ensures industry-grade performance.

Compatibility

This surge protection device is compatible with 3-phase plus neutral TT and TNS electrical systems operating at 230/400V AC. It supports installations requiring DIN rail mounting and is designed to work with backup fuses up to 63 A [gG]. Replacement plugs are available for N-PE and L-N connections, ensuring easy maintenance and component replacement.

Applications

  • Industrial and commercial power distribution panels.
  • Protection of sensitive electrical and electronic equipment from surge damage.
  • Installation in critical infrastructure requiring reliable surge defence.
  • Use in renewable energy systems with TT or TNS configurations.
  • Panel boards in manufacturing plants and large commercial buildings.

Frequently Asked Questions

What is the maximum surge current this device can handle?

The device can handle a maximum discharge current (Imax) of 20 kA (8/20 µs waveform).

Is this SPD suitable for TT systems?

Yes, it is designed for use in TT and TNS system configurations.

Does the device provide remote status indication?

Yes, it features a remote indication system with a green (OK) / not green (replace) microswitch for easy monitoring.

Can this device be installed on a DIN rail?

Yes, the SPD is designed for DIN rail mounting, facilitating easy installation in standard panels.

What is the nominal operating voltage?

The nominal operating voltage is 230/400 V AC.

Common Search Terms

surge protection device, SPD Type 2+3, 20kA surge protector, 4-pole SPD, pluggable surge protector, 3-phase surge protection, TT system SPD, remote indication SPD, industrial surge protector, DIN rail SPD

More Information
Manufacturer Part Number 83230127
Packed Quantity 1
Barcode 8435297849414
Height 70mm
Width 72mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 4 Pole
Voltage 230/400V
Maximum Continuous Voltage 275V
Nominal Discharge Current 10Ka
Remote Indication Yes
System Type TT
Alternative Product SKU STPT23-20K275V-4PG-LFM
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2+3 SPD 4 Pole 230/400 Volt 10KA TT Remote Indication

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo