We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Mersen Surge Protector Type 2+3 SPD 4 Pole 120/208 Volt 10KA TNS
MPN: 83230130
Alt. SKU: STPT23-20K150V-4P
Why Choose the STPT23-20K150V-4P Surge Protection Device?
Engineered for robust protection of 3-phase+neutral 120/208V TNS power systems, this Type 2+3 surge protection device delivers 20kA Imax (8/20μs) discharge capability across four poles for comprehensive safeguarding against transient overvoltages.
Featuring a compact 4-modular, pluggable design for fast installation and easy maintenance, the STPT23-20K150V-4P provides reliable protection for sensitive industrial and commercial equipment, minimising downtime and extending system lifespan.
Technical Specifications
- Item number: 83230130
- Catalogue No: STPT23-20K150V-4P
- Description: Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph+N, 120/208V, 4+0 TNS, 4 Poles, Pluggable, 4 Modules
- EAN/UPC Code: 8435297851127
- RoHS Compliant: Yes
- IEC SPD Type: Class II + III
- Format: Pluggable
- Nominal Operating Volt Rating (Un): 120/208
- AC or DC: AC
- Max Discharge Current : Imax (8/20): 20 kA
- Protection Modes: L-PE / N-PE
- System Configuration: TNS
- Combined Discharge Voltage (1,2/50) (Uoc): 10 kV
- Short Circuit Withstand (ISCCR): 25 kA
- Indication System: Yes
- Indication System Type: Green (OK) / Not green (replace)
- Number of Poles: 4-Pole
- Torque Rating: 3 Nm
- Max. Back-Up Fuse: 63 A [gG]
- Housing Material: PA66 CT1
- MOV Response Time: ≤25
- Installation Mounting: DIN rail
- Replacement Plug L1: 83230001
- Product Width: 72 mm
- Product Length: 70 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.37 kg
- Sell Pack Width: 78 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.35 kg
Product Code: STPT23-20K150V-4P
Key Benefits
- High surge current capacity of 20kA ensures robust protection against transient overvoltages.
- Compact 4-modular pluggable design allows for quick installation and easy maintenance.
- Indication system with green OK status simplifies monitoring and timely replacement.
- Suitable for 3-phase plus neutral TNS power systems at 120/208V, providing versatile application.
- Compliance with RoHS and IEC Class II + III standards guarantees safety and reliability.
- DIN rail mounting facilitates integration into existing electrical panels.
Compatibility
The STPT23-20K150V-4P is compatible with 3-phase plus neutral TNS electrical distribution systems operating at 120/208V AC. It is designed to work seamlessly with standard DIN rail mounted panels and can be integrated with backup fuses rated up to 63 A [gG]. The device supports protection modes L-PE and N-PE, ensuring comprehensive safeguarding of connected equipment.
Applications
- Industrial power distribution systems requiring surge protection.
- Commercial buildings with sensitive electrical and electronic equipment.
- Data centres and server rooms needing reliable transient overvoltage protection.
- Manufacturing plants with critical control systems.
- Renewable energy installations with TNS configuration.
Frequently Asked Questions
What is the maximum surge current this device can handle?
The STPT23-20K150V-4P can handle a maximum discharge current (Imax) of 20kA (8/20μs waveform).
Is this surge protection device suitable for DC systems?
No, this device is designed specifically for AC systems, with a nominal operating voltage of 120/208V AC.
How does the indication system work?
The device features a green indication light when operational. If the indicator is not green, it signals that the device needs to be replaced.
Can this device be installed on a DIN rail?
Yes, the STPT23-20K150V-4P is designed for DIN rail mounting for easy integration into electrical panels.
Common Search Terms
surge protector 3 phase, 120/208V SPD, pluggable surge protection device, Type 2+3 SPD, industrial surge protector, DIN rail SPD, transient voltage suppression, power line surge protector, 20kA surge arrester
| Manufacturer Part Number | 83230130 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297851127 |
| Height | 70mm |
| Width | 72mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 4 Pole |
| Voltage | 120/208V |
| Maximum Continuous Voltage | 150V |
| Nominal Discharge Current | 10Ka |
| System Type | TNS |
| Alternative Product SKU | STPT23-20K150V-4P |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.