We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Mersen Surge Protector Type 2+3 SPD 2 Pole 230 Volt 10KA TNS
MPN: 83230134
Alt. SKU: STPT23-20K275V-2P-LF
Why Choose the STPT23-20K275V-2P-LF Surge Protection Device?
Engineered for reliable protection, this Type 2+3 SPD delivers robust surge suppression up to 20kA (Imax, 8/20 μs) for single-phase TN-S systems at 230V. Its two-pole, pluggable design ensures straightforward installation and maintenance in 2+0 TNS applications.
The leakage current free operation eliminates unwanted tripping or interference, making it ideal for sensitive industrial environments. Compact at 2 modules wide, it provides essential protection for critical loads, ensuring system longevity and compliance with safety standards.
Product Code: 83230134
Key Benefits
- High surge current capacity of 20kA ensures robust protection against transient overvoltages.
- Leakage current free design prevents nuisance tripping and interference with sensitive equipment.
- Compact 2-module width allows for space-saving installation on DIN rail.
- Pluggable format simplifies installation and maintenance, reducing downtime.
- Visual indication system (green/replace) provides clear status monitoring.
- Compliance with IEC Class II + III standards assures reliable performance.
Compatibility
This SPD is compatible with single-phase TN-S systems operating at 230V. It is designed for 2+0 TNS system configurations and fits standard DIN rail mounting systems. Suitable for use with backup fuses up to 63 A [gG]. Replacement plugs 83230003 are available for both N-PE and L-N connections.
Applications
- Industrial electrical panels requiring surge protection.
- Commercial buildings with sensitive electronic equipment.
- Power distribution boards in manufacturing facilities.
- Protection of critical loads in automation and control systems.
- Installation in environments demanding leakage current free operation.
Technical Specifications
- Item number: 83230134
- Catalogue No: STPT23-20K275V-2P-LF
- Description: Surge Protection Device Type 2+3, 20kA Imax (8/20), 1Ph+N, 230/-V, Leakage current free, 2+0 TNS, 2 Poles, Pluggable, 2 Modules
- EAN/UPC Code: 8435297852346
- RoHS Compliant: Yes
- IEC SPD Type: Class II + III
- Format: Pluggable
- Nominal Operating Volt Rating (Un): 230
- AC or DC: AC
- Max Discharge Current : Imax (8/20): 20 kA
- Protection Modes: L-PE / N-PE
- System Configuration: TNS
- Combined Discharge Voltage (1,2/50) (Uoc): 10 kV
- Short Circuit Withstand (ISCCR): 25 kA
- Indication System: Yes
- Indication System Type: Green (OK) / Not green (replace)
- Number of Poles: 2-Pole
- Torque Rating: 3 Nm
- Max. Back-Up Fuse: 63 A [gG]
- Housing Material: PA66 CT1
- MOV Response Time: ≤25
- Installation Mounting: DIN rail
- Replacement Plug N-PE: 83230003
- Replacement Plug L-N: 83230003
- Product Width: 36 mm
- Product Length: 70 mm
- Product Height: 90 mm
- Sell Pack Quantity: 1 EA
- Sell Pack Weight: 0.212 kg
- Sell Pack Width: 42 mm
- Sell Pack Length: 117 mm
- Sell Pack Height: 90 mm
- Product group: Power Line SPDs
- Product Weight: 0.182 kg
Frequently Asked Questions
What type of electrical systems is this SPD suitable for?
The STPT23-20K275V-2P-LF is designed for single-phase TN-S systems operating at 230V, specifically for 2+0 TNS configurations.
Does this device require any maintenance?
The pluggable design allows easy replacement of the SPD modules if the indication system shows a fault (non-green status), simplifying maintenance.
Is this SPD safe for sensitive electronic equipment?
Yes, it features leakage current free operation, which prevents nuisance tripping and interference with sensitive devices.
What is the maximum backup fuse rating for this SPD?
The device supports a maximum backup fuse rating of 63 A [gG].
Common Search Terms
surge protector 230V, Type 2+3 SPD, leakage current free surge device, pluggable surge protector, 20kA surge protection, DIN rail SPD, industrial surge protection device, TN-S system SPD
| Manufacturer Part Number | 83230134 |
|---|---|
| Packed Quantity | 1 |
| Barcode | 8435297852346 |
| Height | 70mm |
| Width | 36mm |
| Depth | 90mm |
| HS Code | 85363090 |
| Country of Manufacture | Spain |
| Manufacturer | Mersen |
| Number of Poles | 2 Pole |
| Voltage | 230V |
| Maximum Continuous Voltage | 275V |
| Nominal Discharge Current | 10Ka |
| System Type | TNS |
| Alternative Product SKU | STPT23-20K275V-2P-LF |

Protection system of coordinated stages: Type 1, 2 and 3 SPDs
The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.
The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.