Do you need some help?

Call us now on: 01706 242050

Mersen Surge Protector Type 2+3 SPD 4 Pole 230/400: 277/480 Volt 10KA TT

MPN: 83230128

Alt. SKU: STPT23-20K320V-4PG

Special Price £105.61 £88.01 Regular Price £140.81

Please contact us for a delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph+N, 230/400; 277/480V, 3+1 TT, 4 Poles, Pluggable, 4 Modules STPT23-20K320V-4PG?

This pluggable surge protection device safeguards critical three-phase installations against transient overvoltages, delivering robust protection with a maximum discharge current of 20kA (8/20µs) across 4 poles for 3Ph+N systems. Its 3+1 TT configuration ensures comprehensive protection suitable for both 230/400V and 277/480V networks.

Designed for ease of maintenance and rapid modular replacement, the STPT23-20K320V-4PG is ideal for industrial environments requiring reliable Type 2+3 SPD performance. Its compact 4-module design streamlines installation in new or retrofit panels, ensuring ongoing system integrity and equipment safety.

Technical Specifications

  • Item number: 83230128
  • Catalogue No: STPT23-20K320V-4PG
  • Description: Surge Protection Device Type 2+3, 20kA Imax (8/20), 3Ph+N, 230/400; 277/480V, 3+1 TT, 4 Poles, Pluggable, 4 Modules
  • EAN/UPC Code: 8435297850793
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II + III
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 230/400
  • AC or DC: AC
  • Max Discharge Current : Imax (8/20): 20 kA
  • Protection Modes: L-N / N-PE
  • System Configuration: TT, TNS
  • Combined Discharge Voltage (1,2/50) (Uoc): 10 kV
  • Following Current (Ifi): 100 A
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace)
  • Number of Poles: 4-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 63 A [gG]
  • Housing Material: PA66 CT1
  • Installation Mounting: DIN rail
  • Uc (L-N): 320 V
  • Uc (N-PE): 255 V
  • Up at In (N-PE): ≤1,5 kV
  • Up at In (L-N): ≤1,4 kV
  • MCOV L-G: 175 V
  • MCOV L-L: 350 V
  • MCOV N-G: 277 V
  • MCOV L-N: 175 V
  • Replacement Plug N-PE: 83230000
  • Replacement Plug L-N: 83230002
  • Product Width: 72 mm
  • Product Length: 70 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.389 kg
  • Sell Pack Width: 78 mm
  • Sell Pack Length: 117 mm
  • Sell Pack Height: 90 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.344 kg

Product Code: 83230128

Key Benefits

  • High surge current capacity of 20kA ensures robust protection against transient overvoltages.
  • Pluggable modular design allows for easy maintenance and quick replacement of components.
  • Suitable for both 230/400V and 277/480V three-phase systems with neutral.
  • Integrated indication system provides clear visual status for operational reliability.
  • Compact 4-module size optimises panel space and simplifies installation.
  • Compatible with TT and TNS system configurations for versatile application.

Compatibility

The STPT23-20K320V-4PG is compatible with three-phase plus neutral (3Ph+N) electrical systems operating at nominal voltages of 230/400V and 277/480V. It supports TT and TNS earthing configurations and is designed for DIN rail mounting, making it suitable for integration into a wide range of industrial and commercial electrical distribution panels.

Applications

  • Industrial electrical distribution boards requiring surge protection.
  • Commercial buildings with three-phase electrical installations.
  • Renewable energy systems needing transient overvoltage protection.
  • Data centres and critical infrastructure to safeguard sensitive equipment.
  • Retrofit projects where modular and pluggable SPD solutions are preferred.

Frequently Asked Questions

What is the maximum surge current this device can handle?

The device can handle a maximum discharge current (Imax) of 20kA with an 8/20µs waveform.

Is this surge protection device suitable for TN-S systems?

Yes, it supports both TT and TNS system configurations for flexible installation options.

How does the indication system work?

The device features a green indicator when operational; if the indicator is not green, the module should be replaced.

Can this SPD be mounted on a DIN rail?

Yes, the STPT23-20K320V-4PG is designed for DIN rail mounting for easy installation.

Are replacement plugs available for this device?

Replacement plugs are available with part numbers 83230000 for N-PE and 83230002 for L-N connections.

Common Search Terms

Surge protection device, SPD Type 2+3, 20kA surge protector, 3 phase plus neutral SPD, pluggable surge protector, DIN rail SPD, industrial surge protection, transient voltage suppressor, STPT23-20K320V-4PG, power line SPD.

More Information
Manufacturer Part Number 83230128
Packed Quantity 1
Barcode 8435297850793
Height 70mm
Width 72mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 4 Pole
Voltage 230/400 and 277/480V
Maximum Continuous Voltage 320V
Nominal Discharge Current 10Ka
System Type TT
Alternative Product SKU STPT23-20K320V-4PG
Write Your Own Review
You're reviewing:Mersen Surge Protector Type 2+3 SPD 4 Pole 230/400: 277/480 Volt 10KA TT

Protection system of coordinated stages: Type 1, 2 and 3 SPDs

The SPDs of a surge protection system must be able to withstand the discharged current and provide a Ures level (residua l voltage) lower than the Ue peak voltage that the equipment can withstand. Most of the times it is not possible to achieve this with just one SPD, especially because the intensity of the surge is not known, and because of the induction of overvoltages when conductors exceed 10m.

The optimal system of protection is the 3-STEP approach, in which successive stages are combined in the performance of high discharge capacity devices and devices with an optimal voltage protection level (low). This is addressed by the definition of "Types" or "Classes" of SPDs according to the type of transient pulses to which each protected zone in the installation is subject to.

Brand Logo