Do you need some help?

Call us now on: 01706 242050

CS AR-02X120 Pizzato Safety module 3NO, category 4

MPN: CS AR-02X120

Alt. SKU: CSAR02X120

Special Price £152.29 £126.91 Regular Price £179.16

Standard Manufacturer Lead Time 4-5 Weeks, Call For Express Delivery Options
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

CS AR-02X120 Pizzato Safety module 3NO, category 4 is available to buy in increments of 1
Free delivery on orders over £200

CSAR-02X120 Safety Relay Module Overview

The Pizzato CSAR-02X120 is a safety relay module from the CS AR series, designed for monitoring emergency stop circuits, safety gate switches, and interlocking devices in industrial machinery.

It belongs to the CS AR-02 family, typically used in applications requiring a 3NO safety output configuration to control multiple safety contactors or distributed safety circuits.

Main Function

  • Monitoring of safety guard doors and interlock switches
  • Emergency stop (E-stop) circuit supervision
  • Safe shutdown of industrial machinery
  • Control of multiple safety contactors via redundant outputs

Key Features

  • Supply voltage: 120 Vac
  • Safety outputs: 3 NO (CS AR-02 configuration)
  • Safety level: Category 4 / PL e / SIL 3
  • Function: Dual-channel safety monitoring for E-stop and guards
  • Mounting: DIN rail (22.5 mm compact housing)
  • Connection: Plug-in screw or spring terminals (variant dependent)

Safety Performance

The CSAR-02X120 is designed for high-risk industrial applications and complies with:

  • EN ISO 13849-1 (Category 4 / PL e)
  • IEC 61508 (SIL 3)

This ensures redundant internal safety architecture and safe failure behavior, meaning any detected fault forces the system into a safe state.

How It Works (Simple Explanation)

  • Door opens → machine stops immediately
  • Emergency stop pressed → power is safely cut
  • Fault detected → system transitions to safe state

Typical Applications

  • Machine guarding systems
  • Industrial automation lines
  • Robotics and conveyor safety systems
  • Packaging machinery
  • General industrial safety circuits

Quick Summary

The CSAR-02X120 is a 120 Vac safety relay module with a 3NO output configuration, used in Category 4 / PL e / SIL 3 safety systems to ensure reliable and redundant machine shutdown in industrial environments.