Lovato’s GE0250T4 is a GE series four‑pole switch disconnector engineered for dependable AC isolation in control panels and power distribution. With an IEC conventional free‑air thermal current of 250 A and screw‑on plate mounting, it integrates cleanly into panel layouts. Fully compliant with IEC/EN 60947‑1 and 60947‑3, it provides reliable multi‑pole switching where clear, safe isolation is required across industrial and commercial installations.
Designed for performance headroom, it offers Ui 1000 V and Uimp 8 kV, with AC23A operational currents of 160 A at 400 V, 125 A at 500 V and 80 A at 690 V. Rated operational power reaches 90 kW at 400 V and 75 kW at 690 V. IP20 frontal protection, 30,000 mechanical cycles, and operation from −25 to 55 °C up to 3000 m underline robust service.
Key Benefits
- Four-pole configuration enables comprehensive multi-circuit AC isolation.
- 250 A Ith delivers robust capacity for demanding distribution duties.
- High Ui 1000 V and 8 kV Uimp for insulation headroom.
- AC21A/AC22A/AC23A ratings suit resistive to inductive load switching.
- Conditional short-circuit strength 100 kA with gG250 fuse protection.
- Screw-on plate mounting streamlines panel integration and assembly.
- IP20 frontal protection and 30,000 mechanical cycles enhance reliability.
Technical Specification
- Product type designation: GE
- Number of poles: 4
- Operating voltage type: AC
- Ith (IEC): 250 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 8 kV
- Operating current Ie AC21A 400 V: 250 A
- Operating current Ie AC21A 500 V: 200 A
- Operating current Ie AC21A 690 V: 180 A
- Operating current Ie AC22A 400 V: 200 A
- Operating current Ie AC22A 500 V: 200 A
- Operating current Ie AC22A 690 V: 160 A
- Operating current Ie AC23A 400 V: 160 A
- Operating current Ie AC23A 500 V: 125 A
- Operating current Ie AC23A 690 V: 80 A
- Power dissipation per pole (max): 9 W
- Rated operational power AC23A 400 V: 90 kW
- Rated operational power AC23A 690 V: 75 kW
- Conditional short-circuit current (rms): 100 kA
- Short-circuit protection fuse: gG250
- Making capacity AC23A 400 V: 1600 A
- Breaking capacity AC23A 400 V: 1280 A
- Mechanical life: 30000 cycles
- Terminal tightening torque (max): 18 Nm
- Operating temperature: -25 to 55 °C
- Storage temperature: -40 to 70 °C
- Max altitude: 3000 m
- IP degree (frontal): IP20
- Pollution degree: 3
What’s Included
- GE0250T4 four-pole switch disconnector unit
- Manufacturer datasheet (online access)
Applications
- Main isolation in industrial control and distribution panels
- Switching of resistive and mixed loads (AC21A/AC22A) within ratings
- Motor and inductive load switching (AC23A) at 400–690 V AC
- OEM equipment requiring four-pole AC disconnection up to 250 A
Frequently Asked Questions
Is the GE0250T4 suitable for AC systems and how many poles does it have?
Which standards does the GE0250T4 comply with?
What are the AC23A operational current ratings?
What short-circuit protection is recommended?
What are the environmental and mounting details?
Safety note: Installation must be performed by qualified personnel. Isolate the supply before work, fit the specified gG250 fuse, and operate within the stated ratings and environmental limits; provide a suitable enclosure as frontal protection is IP20.
| Manufacturer Part Number | GE0250T4 |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975175910 |