We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Lovato GLC0400C1UL UL1008 three-pole changeover switches 400A
MPN: GLC0400C1UL
Alt. SKU: GLC0400 C1UL
Why Choose the GLC0400C1UL?
The Lovato GLC0400C1UL changeover switch is a robust three‑pole UL1008 solution for dependable AC source transfer in demanding installations. Rated at 400 A Ith, it supports industrial switching with high insulation strength (Ui 1000 V) and 12 kV impulse withstand. Screw‑on‑plate mounting simplifies panel integration, while compliance with IEC/EN 60947 standards underpins safety and performance across backup power and distribution changeover duties.
Engineered for reliability, this switch delivers AC23A performance of 200 kW at 400 V and 400 kW at 690 V, with 4,000 A making and 3,200 A breaking capacity at 400 V. It withstands conditional short circuits up to 80 kA with J/400 fuse protection, and offers 10,000 mechanical cycles. Wide operating temperatures from −25 to +55 °C, terminal torque 30–37 Nm and suitability to 3000 m altitude ensure dependable service.
Key Benefits
- UL1008 certified three-pole changeover switch for critical AC applications.
- 400 A Ith and 1000 V Ui provide robust thermal and insulation ratings.
- High 12 kV impulse withstand enhances resilience against transient overvoltage.
- AC23A power up to 400 kW at 690 V for heavy loads.
- Strong making/breaking at 400 V: 4000 A / 3200 A.
- 80 kA conditional short-circuit rating with J/400 fuse protection.
- Wide −25 to +55 °C operating range and 10,000 mechanical cycles.
Technical Specification
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 400 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 12 kV
- Power dissipation per pole (max): 26.0 W
- Rated operational power AC23A 400 V: 200 kW
- Rated operational power AC23A 690 V: 400 kW
- Conditional short-circuit current (rms): 80 kA
- Short-circuit protection fuse: J/400
- Making capacity AC23A 400 V: 4000 A
- Breaking capacity AC23A 400 V: 3200 A
- Mechanical life: 10000 cycles
- Terminal tightening torque: 30 to 37 Nm
- Operating temperature: -25 to +55 °C
- Storage temperature: -40 to +70 °C
- Max altitude: 3000 m
What’s Included
- Lovato GLC0400C1UL three-pole changeover switch
- Product datasheet and installation guidance
- Factory packaging for transit protection
Applications
- Mains-to-generator source transfer for backup power systems
- Changeover in industrial distribution boards and switchboards
- Critical load supply transfer in commercial facilities
- Power switching for industrial equipment and process loads
- Utility or alternative source selection in plant infrastructure
Frequently Asked Questions
Is the GLC0400C1UL certified to recognised standards?
What are the AC23A power ratings?
What short-circuit protection does it require?
What is the operating temperature range?
How is the switch installed?
Safety note: Installation and maintenance must be performed by qualified personnel. Always isolate power, use the specified J/400 fuse, and tighten terminals to 30–37 Nm in accordance with the relevant standards.
| Manufacturer Part Number | GLC0400C1UL |
|---|---|
| Barcode | 8013975267158 |
| HS Code | 85365080 |
| Manufacturer | Lovato |
| Number of Poles | 3 Pole |
| HP/Voltage | 125/240 150/480 350/600 |
| Amperage | 400A |
| Alternative Product SKU | GLC0400 C1UL |