We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
134X2186 Danfoss VLT HVAC Drive 1.1KW/1.5HP 380-480VAC IP66
MPN: 134X2186
Alt. SKU: FC-102P1K1T4Z66H3XGCXOXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 134X2186 VLT HVAC Drive?
The Danfoss 134X2186 is a compact and robust AC variable speed drive (VSD) from the Danfoss VLT® HVAC Drive FC 102 series, designed specifically for heating, ventilation, air conditioning and refrigeration applications. It provides precise motor speed control for pumps, fans, compressors and air handling systems in commercial buildings, industrial facilities and plant room environments.
As part of the proven FC 102 HVAC drive range, this frequency converter combines dedicated HVAC functionality with reliable motor control, helping reduce energy consumption, improve system stability and lower operating costs. Its protected enclosure, graphical control panel and coated PCB design make it suitable for demanding HVAC installations where long-term reliability is essential.
With a rated output power of 1.1 kW (1.5 HP) and a three-phase 380–480 V AC supply, the Danfoss 134X2186 is ideal for smaller HVAC motor applications. The drive features an IP66 / Type 4X enclosure, RFI Class A1/B filtering, graphical local control panel, coated PCB protection and no mains option.
Key Advantages
- Compact HVAC variable speed drive for pumps, fans and compressors.
- 1.1 kW / 1.5 HP output rating suitable for smaller HVAC motor applications.
- Three-phase 380–480 V AC input for industrial and building services power systems.
- IP66 / Type 4X enclosure for demanding installation environments.
- RFI Class A1/B (C1) filtering for EMC compliance.
- Coated PCB for improved environmental protection.
- Graphical local control panel for easier commissioning and monitoring.
Key Features
- Danfoss VLT® HVAC Drive FC 102 series.
- 1.1 kW (1.5 HP) rated output power.
- Three-phase 380–480 V AC input supply.
- IP66 / Type 4X enclosure for protected wall or panel installation.
- No brake chopper.
- RFI Class A1/B (C1) filtering.
- No A option fitted.
- No B option fitted.
- Graphical local control panel for commissioning and monitoring.
- Coated PCB for improved environmental protection.
- No mains option.
- No C1 option and no D option fitted.
- A4 frame format.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC 102
- Model: 134X2186
- Alternative model code: FC-102P1K1T4Z66H3XGCXOXSXXXXAXBXCXXXXDX
- Product type: Variable speed drive / frequency converter
- Rated output power: 1.1 kW
- Horsepower rating: 1.5 HP
- Input voltage: 380–480 V AC
- Input phases: Three-phase
- Frequency: 50 / 60 Hz
- Protection rating: IP66 / Type 4X
- RFI filter: Class A1/B (C1)
- Brake chopper: No brake chopper
- A option: No A option
- B option: No B option
- Local control panel: Graphical LCP
- PCB coating: Coated PCB
- Mains option: No mains option
- Frame size: A4
- Mounting type: Wall / panel mounting
Efficient Motor Control for HVAC Systems
Variable speed drives such as the Danfoss VLT® HVAC Drive FC 102 regulate motor speed by adjusting output voltage and frequency. This allows HVAC equipment to operate according to real system demand, helping reduce energy usage while improving airflow, pressure and temperature control.
The 134X2186 is particularly suitable for smaller HVAC installations requiring a protected enclosure, reliable commissioning interface and long service life. Its IP66 / Type 4X enclosure and coated PCB construction support dependable operation in challenging plant room and building services environments.
Typical Applications
- HVAC fans and ventilation systems.
- Air handling units and building services equipment.
- Small chilled water pumps and condenser pumps.
- Heating and cooling circulation pumps.
- Compressors and refrigeration equipment.
- Plant room motor control systems.
- Commercial building management systems.
- Energy-saving HVAC retrofit projects.
Frequently Asked Questions
What is the Danfoss 134X2186 used for?
The Danfoss 134X2186 is used to control the speed of HVAC motors, including those used on fans, pumps, compressors and air handling equipment.
What motor power is supported by this drive?
This drive is rated for approximately 1.1 kW (1.5 HP) motor control applications.
What supply voltage does the drive require?
The 134X2186 operates from a three-phase 380–480 V AC supply.
What enclosure rating does the Danfoss 134X2186 have?
The drive has an IP66 / Type 4X enclosure, making it suitable for demanding HVAC and plant room environments requiring strong environmental protection.
Does the Danfoss 134X2186 include a coated PCB?
Yes. This configuration includes a coated PCB, which helps improve protection in challenging operating environments.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC drives are trusted by building services engineers, facilities managers and automation specialists for efficient motor control, reliable operation and seamless integration into modern HVAC systems.
| Manufacturer Part Number | 134X2186 |
|---|---|
| Barcode | 5710108082826 |
| Height | 390mm |
| Width | 200mm |
| Depth | 175mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP66 |
| KW Rating | 1.1kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P1K1T4Z66H3XGCXOXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.