131U9836 Danfoss VLT FC-102 HVAC Drive 1.5 KW / 2.0 HP, 380 - 480 VAC, IP55

MPN: 131U9836

Alt. SKU: FC-102P1K5T4Z55H2XNXXOXSXXXXAXBXCXXXXDX

Special Price £583.92 £486.60 Regular Price £973.20

Please contact us for delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Danfoss 131U9836 VLT HVAC Drive?

The Danfoss 131U9836 is a reliable and energy-efficient AC variable frequency drive (VFD) designed for accurate speed control of motors used in heating, ventilation, air conditioning and refrigeration systems. As part of the proven Danfoss VLT® HVAC Drive FC 102 series, it is engineered to help reduce energy consumption, improve motor performance and support dependable HVAC system operation.

This drive provides application-focused control for fans, pumps and compressors, making it suitable for commercial buildings, industrial facilities and plant room installations. The FC 102 series includes dedicated HVAC functions that simplify commissioning, improve system efficiency and reduce the need for additional external control equipment.

With a rated output power of 1.5 kW and a three-phase 380–480 V AC supply, the 131U9836 is well suited to smaller HVAC motor control applications. Its IP55 / Type 12 enclosure offers enhanced protection for demanding environments, while the A4 frame format supports practical installation in building services and industrial control systems.

Key Advantages

  • Dedicated HVAC variable frequency drive for fans, pumps and compressors.
  • 1.5 kW motor power rating suitable for smaller HVAC applications.
  • Three-phase 380–480 V AC input compatible with commercial and industrial power systems.
  • IP55 / Type 12 enclosure for enhanced environmental protection.
  • Integrated RFI filtering supports electromagnetic compatibility.
  • Numerical local control panel for straightforward setup and monitoring.
  • Efficient motor speed control helps reduce energy usage and mechanical wear.

Key Features

  • Danfoss VLT® HVAC Drive FC 102 series.
  • 1.5 kW rated output power.
  • 2.0 HP motor rating.
  • 4.1 A continuous output current.
  • Three-phase 380–480 V AC input supply.
  • IP55 / Type 12 enclosure protection.
  • H2 RFI filter / RFI Class A2 (C3).
  • No brake chopper configuration.
  • Numerical Local Control Panel.
  • A4 frame size for compact HVAC installations.

Technical Specifications

  • Manufacturer: Danfoss
  • Series: VLT® HVAC Drive FC 102
  • Model: 131U9836
  • Type code: FC-102P1K5T4Z55H2XNXXOXSXXXXAXBXCXXXXDX
  • Product type: AC variable frequency drive / frequency converter
  • Rated output power: 1.5 kW
  • Motor rating: 2.0 HP
  • Continuous current: 4.1 A
  • Intermittent current: 4.51 A
  • Input voltage: 380–480 V AC
  • Input phases: 3-phase
  • kVA rating: 2.84 kVA
  • Protection rating: IP55 / Type 12
  • Frame size: A4
  • RFI filter: H2 RFI filter / RFI Class A2 (C3)
  • Brake chopper: Not included
  • Control panel: Numerical Local Control Panel
  • Dimensions (H × W × D): approx. 391 × 200 × 177 mm
  • Weight: approx. 7.3 kg

Efficient Motor Control for HVAC Systems

Variable frequency drives such as the Danfoss 131U9836 regulate motor speed by adjusting output frequency and voltage. This allows HVAC equipment to operate in line with real system demand, reducing unnecessary energy consumption while improving comfort, process stability and equipment service life.

The VLT® HVAC Drive FC 102 series is designed for building services professionals who need dependable motor control for pumps, fans and refrigeration equipment. Its application-specific functions, robust enclosure and practical interface make it suitable for both new installations and like-for-like replacement projects.

Typical Applications

  • Air handling units and ventilation systems.
  • HVAC pumps and circulation systems.
  • Commercial building services.
  • Cooling towers and condenser fans.
  • Refrigeration and chiller systems.
  • Industrial fan and pump control.

Frequently Asked Questions

What is the Danfoss 131U9836 used for?

The Danfoss 131U9836 is used to control the speed of AC motors in HVAC applications such as fans, pumps, compressors and ventilation systems.

What motor power is supported by this drive?

The drive supports motors with a rated output power of approximately 1.5 kW / 2.0 HP.

What supply voltage does the drive require?

The 131U9836 operates from a three-phase 380–480 V AC supply.

What enclosure rating does this drive have?

The drive features an IP55 / Type 12 enclosure, providing enhanced protection for demanding HVAC and industrial environments.

Does the Danfoss 131U9836 include a brake chopper?

No, this specific configuration is supplied without an integrated brake chopper.

Trusted by HVAC Professionals Worldwide

Danfoss VLT HVAC Drives are trusted by facilities managers, HVAC engineers and building services professionals for reliable motor control, energy-efficient operation and long-term system performance.
More Information
Manufacturer Part Number 131U9836
Barcode 5710107014927
Height 390mm
Width 200mm
Depth 175mm
Filter Filter Included
Input Phases Three Phase
Degree of protection (IP) IP55
KW Rating 1.5kW
Output Phases Three phase
VSD Range Danfoss VLT FC102
Manufacturer Danfoss
Alternative Product SKU FC-102P1K5T4Z55H2XNXXOXSXXXXAXBXCXXXXDX
Write Your Own Review
You're reviewing:131U9836 Danfoss VLT FC-102 HVAC Drive 1.5 KW / 2.0 HP, 380 - 480 VAC, IP55

The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.

The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.

Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.

Supply voltages and power range

3 x 200-240 V...1.1-45 kW

3 x 380-480 V...1.1 kW – 1 MW

3 x 525-600 V...1.1-90 kW

3 x 525-690 V...45 kW – 1.4 MW

Low harmonic drive

3 x 380-480 V...132-710 kW

12-pulse drive

3 x 380-480 V...250-200kW

Features and benefits

  • There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
  • PLC capacity is often unnecessary thanks to the Smart Logic Controller 
  • A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
  • The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
  • 5–15% energy is saved as a result of the Automatic Energy Optimization function
  • Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity

 

Applications

Pumps, fans, compressors.

PC tools

VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box

For further information on this product please get in touch with our team or visit the Danfoss website.