We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131U1484 Danfoss VLT FC-102 HVAC Drive 4.0 KW / 5.5 HP, 380 - 480 VAC, IP55
MPN: 131U1484
Alt. SKU: FC-102P4K0T4Z55H3XGXXXXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131U1484 VLT® HVAC Drive FC-102?
The Danfoss 131U1484 is a robust and efficient variable frequency drive (VFD) designed for accurate speed control of three-phase motors in heating, ventilation, air conditioning and refrigeration systems. As part of the proven Danfoss VLT® HVAC Drive FC-102 series, it is engineered to improve HVAC efficiency, reduce energy consumption and deliver dependable motor control in commercial and industrial environments.
This drive provides advanced HVAC-specific functionality, reliable motor regulation and straightforward integration into building automation systems. The FC-102 platform is widely used for fans, pumps and compressors where precise control, energy savings and long service life are essential.
With a rated output power of 4.0 kW / 5.5 HP and a three-phase 380–480 V AC supply, the Danfoss 131U1484 is ideal for medium-duty HVAC motor applications. Its IP55 / Type 12 A4 frame enclosure offers strong protection for demanding installation environments while supporting reliable operation and easy commissioning.
Key Advantages
- Dedicated HVAC variable frequency drive for fans, pumps and refrigeration equipment.
- 4.0 kW / 5.5 HP power rating suitable for commercial building services applications.
- Three-phase 380–480 V AC input compatible with industrial power systems.
- IP55 / Type 12 enclosure for reliable operation in demanding environments.
- Integrated RFI Class A1/B (C1) filter for improved EMC performance.
- Graphical local control panel for simple setup, monitoring and operation.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 4.0 kW / 5.5 HP rated output power.
- Three-phase 380–480 V AC input supply.
- IP55 / Type 12 A4 frame enclosure.
- Integrated RFI Class A1/B (C1) filter.
- No brake chopper configuration.
- Graphical local control panel included.
- Not coated PCB configuration.
- No mains option fitted.
- Latest standard software release.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P4K0T4Z55H3XGXXXXSXXXXAXBXCXXXXDX
- SKU: 131U1484
- Product type: Variable frequency drive / frequency converter
- Rated output power: 4.0 kW / 5.5 HP
- Input voltage: 380–480 V AC
- Input phases: Three-phase
- Output frequency: 0–590 Hz
- Protection rating: IP55 / Type 12
- Frame size: A4
- RFI filter: H3 / Class A1/B (C1)
- Brake chopper: No
- Control panel: Graphical local control panel
- PCB coating: Not coated
- Net weight: approx. 7.94 kg
- Gross weight: approx. 8.68 kg
- EAN: 5702427925441
Reliable Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss VLT® HVAC Drive FC-102 regulate motor speed by adjusting the voltage and frequency supplied to the motor. This allows HVAC systems to match output to real demand, helping reduce energy use, improve comfort control and minimise mechanical stress on equipment.
The FC-102 series is purpose-built for HVAC engineers, building services contractors and facility managers. Its dedicated application features, integrated filtering and rugged enclosure design make it a practical choice for new installations, upgrades and like-for-like drive replacements.
Typical Applications
- Air handling units and ventilation systems.
- Supply and extract fans.
- Heating and chilled water circulation pumps.
- Commercial refrigeration systems.
- Building management and automation systems.
- Energy efficiency upgrades in commercial buildings.
Frequently Asked Questions
What is the Danfoss 131U1484 used for?
The Danfoss 131U1484 is used to control the speed of three-phase motors in HVAC, ventilation, heating, cooling and refrigeration applications.
What motor power is supported by this drive?
This drive provides a rated output power of approximately 4.0 kW / 5.5 HP.
What supply voltage does the drive require?
The Danfoss 131U1484 operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
The drive features an IP55 / Type 12 enclosure, making it suitable for demanding HVAC and building services environments.
Does this model include a local control panel?
Yes, this configuration includes a graphical local control panel for commissioning, operation and monitoring.
Trusted by HVAC Professionals Worldwide
Danfoss VLT® HVAC Drive FC-102 frequency converters are widely used by building services engineers, HVAC specialists and facility managers to deliver reliable motor control, energy efficiency and long-term operational performance.
| Manufacturer Part Number | 131U1484 |
|---|---|
| Barcode | 5702427925441 |
| Height | 391mm |
| Width | 200mm |
| Depth | 177mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 4kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P4K0T4Z55H3XGXXXXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.