We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
S804C-C63 High Performance MCB
MPN: 2CCS884001R0634
Alt. SKU: S804C-C63
Why Choose the S804C-C63 [2CCS884001R0634]
The S804C-C63 is a 4-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 63 A. It is a current limiting device with a maximum breaking capacity of 25kA at 240/415V. It can be used for voltages up to 254/440V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S804C-C63 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S804C-C63 more comfortable. Due to the fast arc extinction of S804C-C63 your application will be secured.
Technical Specification
- Function: 4-pole high performance circuit breaker with C-characteristic, thermal and electromechanic trip mechanisms for overload and short circuit protection.
- Rated Current: 63 A.
- Rated Ultimate Short-Circuit Breaking Capacity (Icu): 25 kA at 415 V AC, 15 kA at 440 V AC, 10 kA at 500 V DC.
- Rated Service Short-Circuit Breaking Capacity (Ics): 25 kA at 415 V AC, 10 kA at 440 V AC, 10 kA at 500 V DC.
- Contact Configuration: 4 poles with ON/OFF/TRIP indication.
- Terminal Type and Capacity: Cage screw terminals for copper conductors; flexible 0–50 mm², rigid 0–70 mm².
- Protection Rating: IP40 in enclosure with cover.
- Mechanical Endurance: 4000 cycles; Electrical Endurance: 6000 cycles.
- Tightening Torque: 3.5 N·m (31 in·lb).
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the rated current of the S804C-C63 circuit breaker?
What is the maximum breaking capacity of the S804C-C63?
What types of tripping mechanisms does the S804C-C63 have?
What is the terminal type and capacity for the S804C-C63?
Is the S804C-C63 suitable for residential and industrial applications?
What is the protection rating of the S804C-C63?
What standards does the S804C-C63 comply with?
| Manufacturer Part Number | 2CCS884001R0634 |
|---|---|
| Height | 95mm |
| Width | 106mm |
| Depth | 82.5mm |
| Number of Poles | 4 Pole |
| Trip Curve Type | C |
| HS Code | 85362010 |
| Country of Manufacture | Switzerland |
| Manufacturer | ABB |
| Alternative Product SKU | S804C-C63 |
| Barcode | 7612271213435 |