ABB S201M-D10 MCB - S200M - 1P - D - 10A
MPN: 2CDS271001R0101
Alt. SKU: S201M-D10
Why Choose the S201M-D10 [2CDS271001R0101]
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
Technical Specification
- Function: Current limiting miniature circuit breaker with thermal and electromechanical tripping for overload and short circuit protection.
- Voltage Ratings: Up to 400 V AC, 60 V DC.
- Current Rating: Rated current up to 63 A; model S201M-D10 rated at 10 A.
- Contact Configuration: Single pole (1P) with red ON / green OFF position indication.
- Breaking Capacity: Rated ultimate breaking capacity up to 25 kA (133 V AC), 15 kA (230/400 V AC).
- Terminal Type and Capacity: Screw terminals; flexible cables 0.75–25 mm², rigid cables 0.75–35 mm², busbar up to 10 mm².
- Electrical and Mechanical Endurance: 20,000 cycles each.
- Insulation and Impulse Rating: Dielectric test voltage 2 kV (50/60 Hz, 1 min); Energy limiting class 3.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the function of the S200M miniature circuit breakers?
What are the available configurations for the S200M MCBs?
What is the breaking capacity of the S200M circuit breakers?
What is the maximum rated current for the S200M MCBs?
What type of cables can be connected to the S200M circuit breakers?
Can auxiliary contacts be mounted on the S200M MCBs?
What standards do the S200M MCBs comply with?
| Manufacturer Part Number | 2CDS271001R0101 |
|---|---|
| Amperage | 10A |
| Number of Poles | 1 Pole |
| Trip Curve Type | Type B 10KA |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S201M-D10 |
| Barcode | 4016779599429 |