We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
YDSW11230 Lovato star delta starter with isolator 230V 11KW 15HP 22Amp
MPN: YDSW11230
Why Choose the Lovato YDSW11230 Star-Delta Starter with Isolator?
The Lovato YDSW11230 is a high-performance star-delta motor starter with integrated isolator designed for reduced-current starting of three-phase induction motors in demanding industrial and commercial applications. Manufactured by Lovato Electric, this enclosed starter combines dependable motor control with safe local isolation functionality for enhanced operational safety and maintenance convenience.
The star-delta starting method initially connects the motor windings in a star configuration to reduce startup current and torque before automatically switching to delta operation for normal running conditions. This controlled startup process helps reduce voltage dips, minimise mechanical stress and improve the operational lifespan of motors and driven equipment.
With a rated motor power of 11 kW, a 22 A AC3 operational current rating and a 230 V AC control voltage, the Lovato YDSW11230 is suitable for pumps, compressors, conveyors, fans and industrial process machinery requiring reliable reduced-current motor starting with integrated isolation functionality.
Key Advantages
- Reliable star-delta starter with integrated rotary isolator.
- 11 kW motor rating suitable for industrial machinery.
- 22 A AC3 operational current capability.
- Reduces motor starting current and mechanical stress.
- 230 V AC control voltage for industrial control systems.
- IP65 insulated enclosure suitable for demanding environments.
- Compatible with RF38 thermal overload relays for motor protection.
Key Features
- Lovato L-Starter YDSW series.
- 11 kW rated motor power.
- 22 A maximum AC3 current.
- 230 V AC control voltage.
- Automatic star-delta transition for controlled motor startup.
- Integrated rotary isolator for local disconnection.
- Heavy-duty insulated polycarbonate enclosure.
- Designed for use with RF38 overload relays.
Technical Specifications
- Manufacturer: Lovato Electric
- Series: L-Starter YDSW Series
- Model: YDSW11230
- Product type: Star-delta starter with isolator
- Rated motor power: 11 kW
- Horsepower rating: 15 HP
- Maximum AC3 current: 22 A
- Control voltage: 230 V AC
- Input phases: 3-phase
- Protection rating: IP65 enclosure
- Enclosure material: Insulated polycarbonate
- Mounting type: Surface mounting
- Dimensions (H × W × D): approx. 220 × 280 × 170 mm
- Overload relay compatibility: RF38 series
- Starting method: Automatic star-delta transition
- Compliance: IEC/EN 60947-1, IEC/EN 60947-4-1
Efficient Reduced-Current Motor Starting with Isolation
Star-delta starters are commonly used for larger three-phase motors where reducing startup current is essential for maintaining electrical system stability and protecting connected equipment. By initially connecting the motor in star configuration, the starter lowers current draw before automatically switching to delta operation for full-load running.
The integrated rotary isolator fitted to the Lovato YDSW11230 enables safe local disconnection during maintenance and servicing procedures. This combination of star-delta starting and isolation functionality makes the starter particularly suitable for industrial automation systems requiring both operational reliability and maintenance safety.
Typical Applications
- Industrial pumps and booster systems.
- Compressors and refrigeration equipment.
- Conveyor and material handling systems.
- Ventilation and extraction equipment.
- Water treatment and agricultural systems.
- General industrial machinery and automation systems.
Frequently Asked Questions
What is the Lovato YDSW11230 used for?
The YDSW11230 is used for reduced-current star-delta starting of three-phase induction motors with integrated local isolation functionality.
What motor size can this starter control?
This starter is designed for motors rated up to approximately 11 kW or 15 HP.
Why use a star-delta starter instead of direct-on-line starting?
Star-delta starters reduce motor starting current and mechanical stress, helping to protect electrical systems and connected machinery during startup.
Does the starter include overload protection?
No. The YDSW11230 requires a compatible RF38 thermal overload relay to provide motor overload protection.
What voltage does the control circuit use?
The starter uses a 230 V AC control voltage.
Trusted by Industrial Engineers Worldwide
Lovato star-delta starters with integrated isolators are widely trusted by OEM machine builders, panel manufacturers and industrial maintenance engineers for reliable reduced-current motor starting and dependable long-term industrial performance.
| Manufacturer Part Number | YDSW11230 |
|---|---|
| HS Code | 85371098 |
| KW Rating | 11kW |
| Enclosed | Yes |
| Coil Voltage | 230V |
| Manufacturer | Lovato |
| Amperage | 22A |