BFK1810A12060 - 3P CONTACTOR 15KVAR 120V 60HZ
MPN: BFK1810A12060
Why Choose the BFK1810A12060?
The Lovato BFK1810A12060 is a contactor for power factor correction with an AC control circuit, designed to switch capacitor banks reliably. Supplied with limiting resistors and a 120 VAC 60 Hz coil, this 3‑pole device delivers up to 15 kvar at 400 V. It features a built‑in 1NO auxiliary contact and supports screw or 35 mm DIN rail mounting for fast panel integration.
Built on the BFK18 platform, it offers Ui 690 V, Uimp 6 kV and Ith 32 A for robust service. A mechanical life of 20,000,000 cycles and 1.5–1.8 Nm terminal torque suit demanding environments from −50 to 70 °C. Rated for Pollution Degree 3 and up to 3000 m, it conforms to IEC/EN/BS, UL and CSA 60947 standards.
Key Benefits
- Integrated limiting resistors for smooth capacitor switching in PFC applications.
- 15 kvar at 400 V performance from a compact 3-pole design.
- 120 VAC 60 Hz coil for straightforward AC control circuit integration.
- Built-in 1NO auxiliary contact simplifies signalling and interlocking.
- Flexible screw or 35 mm DIN rail mounting options.
- High endurance: 20,000,000 mechanical cycles for long service life.
- Robust insulation: Ui 690 V, Uimp 6 kV for reliability.
Technical Specification
- Product type designation: BFK18
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 32 A
- Terminal tightening torque: 1.5 to 1.8 Nm
- Weight: 418 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Contactor unit with integrated limiting resistors
- Built-in 1NO auxiliary contact
- 120 VAC 60 Hz coil (pre-fitted)
- Installation and safety information
Applications
- Automatic power factor correction capacitor bank switching at 400 V
- Reactive power compensation in industrial and commercial panels
- Three-phase distribution boards requiring AC control circuit contactors
- PFC systems up to 15 kvar at 400 V
Frequently Asked Questions
What is the coil voltage and frequency?
How many poles and auxiliary contacts does it have?
What mounting options are available?
What is the maximum operational power at 400 V?
Which standards does this model comply with?
Safety note: Install and commission only by qualified personnel. Isolate the supply before work, observe specified tightening torque and operating temperatures, and follow applicable IEC/EN/BS 60947 requirements.
| Manufacturer Part Number | BFK1810A12060 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975163634 |
| Coil Voltage | 120V |