We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK1210A12060 - 3P CONTACTOR 12 5KVAR 120V 60HZ
MPN: BFK1210A12060
Why Choose the BFK1210A12060?
Lovato BFK1210A12060 is a contactor for power factor correction with AC control circuit, engineered for reliable capacitor switching. Delivering 12.5kvar at 400V, it features an AC coil rated 120VAC 60Hz, three poles and a 1NO auxiliary. Built-in limiting resistors reduce inrush. Flexible screw or 35mm DIN rail mounting supports fast panel integration.
Part of the BFK12 range, it carries Ui 690 V and Uimp 6 kV, with Ith 28 A and terminal torque 1.5–1.8 Nm. Rated for 20,000,000 mechanical cycles, it operates from -50 to 70 °C and stores from -60 to 80 °C. Suitable up to 3000 m, Pollution Degree 3, and conforms to IEC/EN/BS, UL and CSA standards.
Key Benefits
- Optimised for power factor correction with AC control circuit.
- Built-in limiting resistors for controlled capacitor inrush currents.
- 12.5kvar operational power at 400 V for dependable PFC steps.
- 120 VAC 60 Hz coil for consistent control performance.
- Three-pole design with 1NO auxiliary contact included.
- Robust insulation: Ui 690 V and Uimp 6 kV ratings.
- Durable construction with 20,000,000 mechanical life cycles.
- Quick screw or 35 mm DIN rail mounting options.
Technical Specification
- Product type designation: BFK12
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 28 A
- Terminal tightening torque: 1.5 to 1.8 Nm
- Weight: 416 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK1210A12060 contactor with built-in limiting resistors
- Installation and safety instructions
- Manufacturer datasheet (PDF)
Applications
- Switching power factor correction capacitors at 400 V
- Automatic power factor correction panels
- Industrial and commercial LV distribution boards
- OEM control panels requiring AC-controlled PFC contactors
- Retrofit upgrades of power factor correction stages
Frequently Asked Questions
What is the coil voltage and frequency?
What is the IEC operational power at 400 V?
How is the contactor mounted?
What auxiliary contact is included?
Which standards does it conform to?
Safety note: Install and commission only by qualified personnel. Isolate power, discharge capacitors before work, and adhere to the specified ratings, torque values and applicable standards.
| Manufacturer Part Number | BFK1210A12060 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975163627 |
| Coil Voltage | 120V |