We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK11500A400 - CONTACTOR FOR PFC 75KVAR 400VAC 50/60HZ
MPN: BFK11500A400
Why Choose the BFK11500A400?
Engineered for reliable capacitor switching, the Lovato BFK11500A400 is a contactor for power factor correction with an AC control circuit. It delivers up to 75 kVAr at 400 V, features a 3‑pole design, and uses a 400 VAC 50/60 Hz coil. Mounting is flexible via screw fixing or 35 mm DIN rail, streamlining integration in PFC panels and three‑phase switchboards.
Built for demanding environments, the BFK115 series offers Ui 690 V, Uimp 8 kV and Ith 160 A, with a mechanical life of 15,000,000 cycles. Operating temperature spans −50 to 70 °C and storage −60 to 80 °C, with use up to 3000 m altitude, pollution degree 3. Conformity to IEC/EN/BS 60947 and UL/CSA standards supports consistent performance.
Key Benefits
- Rated 75 kVAr at 400 V for effective capacitor bank switching.
- 400 VAC 50/60 Hz coil suits standard AC control circuits.
- Three-pole configuration for three-phase power factor correction.
- Includes limiting resistors for dedicated PFC applications.
- Screw or 35 mm DIN rail mounting for fast installation.
- High dielectric strength: Ui 690 V and Uimp 8 kV.
- Long mechanical life of 15,000,000 cycles for durability.
- Wide operating temperature −50 to 70 °C for harsh sites.
Technical Specification
- Product type designation: BFK115
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 8 kV
- Ith (IEC): 160 A
- Terminal tightening torque: 6 to 7 Nm
- Weight: 2095 g
- Mechanical life: 15000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK11500A400 contactor, 3-pole, with limiting resistors
- 400 VAC 50/60 Hz control coil pre-fitted
- Installation and safety information leaflet
Applications
- Power factor correction capacitor banks in three-phase systems
- Industrial PFC panels and switchboard assemblies
- Retrofit or upgrade of existing power factor correction stages
- OEM equipment requiring dedicated PFC contactors with AC control
Frequently Asked Questions
What is the operational power rating at 400 V?
What coil voltage and frequency does this model use?
How can the contactor be mounted?
Which standards does the product conform to?
Are limiting resistors included?
Safety note: Installation must be carried out by qualified personnel with power isolated. Follow manufacturer instructions and applicable IEC/EN 60947 standards; tighten terminals to 6–7 Nm and observe all rated limits.
| Manufacturer Part Number | BFK11500A400 |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975239940 |
| Coil Voltage | 400VAC |