1SFL677001R7011 af1650-30-11-70 100-250v 50/60hz-dc ABB Contactor

SKU
AF1650-30-11
Special Price £7,418.02 £6,181.68 Regular Price £10,597.16

Please contact us for a delivery time

1SFL677001R7011

Dimensions
Product Net Width: 438.0 mm
Product Net Depth: 244.0 mm
Product Net Height: 392.0 mm
Product Net Weight: 33.000 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1650 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 1450 A
(690 V) 40 °C 1650 A
(1000 V) 40 °C 1650 A
(1000 V) 55 °C 1450 A
(690 V) 70 °C 1270 A
(1000 V) 70 °C 1270 A
Rated Operational Current AC-3 (Ie):
(690 V) 55 °C 970 A
(500 V) 55 °C 970 A
(440 V) 55 °C 1060 A
(415 V) 55 °C 1060 A
(380 / 400 V) 55 °C 1060 A
(220 / 230 / 240 V) 55 °C 1060 A
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 315 kW
(380 / 400 V) 560 kW
(415 V) 630 kW
(440 V) 710 kW
(500 V) 710 kW
(690 V) 1000 kW
(1000 V) 600 kW
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A
Maximum Electrical Switching Frequency:
AC-3 60 cycles per hour
AC-1 60 cycles per hour
AC-2 / AC-4 60 cycles per hour
Rated Operational Current DC-1 (Ie):
(850 V) 3 Poles in Series, 40 °C 1650 A
(600 V) 3 Poles in Series, 40 °C 1650 A
(220 V) 3 Poles in Series, 40 °C 1650 A
Rated Operational Current DC-3 (Ie):
(850 V) 3 Poles in Series, 40 °C 1650 A
(600 V) 3 Poles in Series, 40 °C 1650 A
(220 V) 3 Poles in Series, 40 °C 1650 A
Rated Operational Current DC-5 (Ie):
(850 V) 3 Poles in Series, 40 °C 1650 A
(600 V) 3 Poles in Series, 40 °C 1650 A
(220 V) 3 Poles in Series, 40 °C 1650 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 0.5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 100 … 250 V
50 Hz 100 … 250 V
DC Operation 100 … 250 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A
Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A
Operate Time:
Between Coil Energization and NO Contact Closing 50 ... 80 ms
Between Coil De-energization and NO Contact Opening 35 ... 55 ms
Between Coil De-energization and NC Contact Closing 35 ... 55 ms
Between Coil Energization and NC Contact Opening 50 ... 80 ms
Connecting Capacity Main Circuit:
Bar 100 mm
Connecting Capacity Auxiliary Circuit:
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 1x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars

Environmental
Ambient Air Temperature:

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
Maximum Operating Altitude Permissible: 3000 m
RoHS Status: No declaration needed

Technical UL/CSA
Maximum Operating Voltage UL/CSA: 
Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 1650 A
Horsepower Rating UL/CSA:
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1150 Hp
(220 ... 240 V AC) Three Phase 450 Hp
More Information
Manufacturer ABB
kW Rating 560KW
Inbuilt Aux 1 N/O, 1 N/C
Alternative Product SKU 1SFL677001R7011
Manufacturer Part Number AF1650-30-11
Product Lead Time Please contact us for a delivery time
Links Click here for link to ABB website info (opens in new tab)
Write Your Own Review
You're reviewing:1SFL677001R7011 af1650-30-11-70 100-250v 50/60hz-dc ABB Contactor

ABB AF Contactor Range

ABB contactor range can be used to control power circuits up to a level of 690 V AC and 220 V DC. The main benefit of ABB's range of AF products are that only a few coils are needed for different control voltages used in many applications without having to change the coil.

These four coil voltages run from between 24...500 V 50/60 Hz or 20...500 V DC. These are AC/DC dual rated which cover a range of amperages rather than set specifications. ABB's AF contactors have built in surge protection and do not require any other surge suppressors.

Accessories are available in the form of front and side mounted auxiliary contact blocks plus being designed as a 1 stack 3 pole block type contactor they can have a one main auxiliary contact. Replacement parts are available as well as other accessories.

You can click on this link to view more ABB information

Latest News

Hello to our newest fans: introducing the Finder 7F range

Hello to our newest fans: introducing the Finder 7F range

April 23, 2024 Read full
5 top benefits of energy monitoring equipment for your business

5 top benefits of energy monitoring equipment for your business

April 16, 2024 Read full
Why choose the Rittal VX25 range for your operations?

Why choose the Rittal VX25 range for your operations?

March 26, 2024 Read full
4 key avenues to help increase efficiency in your operations

4 key avenues to help increase efficiency in your operations

March 21, 2024 Read full