abb softstarter PSR12-600-70 110-240vac control voltage psr range 12 amp
MPN: 1SFA896106R7000
Alt. SKU: PSR12-600-70
Why Choose the PSR12-600-70 [1SFA896106R7000]
The softstarter PSR12-600-70 has a rated maximum operational current of 12 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specification
- Function: Soft start and stop with voltage ramp.
- Rated Operational Voltage: 208 ... 600 V AC.
- Rated Operational Current: 12 A.
- Control Supply Voltage: 100 ... 240 V AC, 50/60 Hz.
- Run Signal Relay: Normally Open (NO) contact included.
- Degree of Protection: IP20 (main terminals).
- Terminal Type: Screw terminals.
- Connecting Capacity: Main circuit: rigid 1/2 x 0.75 ... 2.5 mm²; Control circuit: 1 or 2 x 0.75 ... 2.5 mm².
- Tightening Torque: 1 N·m for control, main and supply circuits.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum operational current of the PSR12-600-70?
What is the operating voltage range for the PSR12-600-70?
Can the PSR12-600-70 be used with a manual motor starter?
What is the degree of protection for the PSR12-600-70?
What is the connecting capacity for the main circuit?
How can I enable Fieldbus communication on the PSR12-600-70?
What are common applications for the PSR12-600-70?
| Manufacturer Part Number | 1SFA896106R7000 |
|---|---|
| Barcode | 7320500338247 |
| Max Rated Current | 12 Amps |
| Motor Power (kW) at 400V | 5.5Kw |
| Motor Power (kW) at 500V | 5.5Kw |
| Product Image | For Illustration Purposes Only |
| KW Rating | 5.5kW |
| Manufacturer | ABB |
| Alternative Product SKU | PSR12-600-70 |
| Product Lead Time | Delivery 7-10 Days |