Engineered for dependable capacitor switching, the Lovato BFK11500A024 is a contactor for power factor correction with an AC control circuit. It includes integrated limiting resistors to control inrush, a 24 VAC 50/60 Hz coil and a 3‑pole layout delivering up to 75 kvar at 400 V. Based on the BFK115 platform, it’s ideal for low‑voltage PFC panels needing consistent performance.
Installation is straightforward via screw fixing or 35 mm DIN rail, with rugged electrical ratings: Ui 690 V, Uimp 8 kV and Ith 160 A. Designed for durability, it offers 15,000,000 mechanical cycles, operates from −50 to 70 °C and up to 3000 m altitude, Pollution Degree 3. Conforms to IEC/EN/BS 60947-1 and 60947-4-1, with UL and CSA references, plus Sustainability certification.
Key Benefits
- Integrated limiting resistors reduce capacitor inrush for smoother engagement.
- 75 kvar at 400 V supports substantial power factor correction stages.
- 24 VAC 50/60 Hz coil simplifies control in common AC panels.
- Three-pole design for balanced three-phase capacitor switching.
- Screw or 35 mm DIN rail mounting speeds panel assembly.
- Robust Ui 690 V, Uimp 8 kV, Ith 160 A ratings.
- Long mechanical life of 15,000,000 cycles for reliability.
Technical Specification
- Product type designation: BFK115
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 8 kV
- Ith (IEC): 160 A
- Terminal tightening torque: 6 to 7 Nm
- Weight: 2095 g
- Mechanical life: 15000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK11500A024 contactor unit for power factor correction
- Integrated limiting resistors for capacitor inrush control
- 24 VAC 50/60 Hz coil installed
- Mounting interfaces for DIN rail 35 mm or screw fixing
Applications
- Low-voltage power factor correction capacitor banks at 400 V
- Industrial and commercial switchboards and distribution panels
- Automated PFC stages in control and compensation panels
- HVAC and process plants requiring reactive power compensation
Frequently Asked Questions
What coil voltage and frequency does the BFK11500A024 require?
Is it suitable for 400 V capacitor banks?
Does this contactor include limiting resistors?
How can the contactor be mounted in a panel?
Which standards does this product conform to?
Safety note: Install and service only by qualified personnel. Isolate all power sources and observe the specified electrical and environmental ratings and applicable standards before commissioning.
| Manufacturer Part Number | BFK11500A024 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975239858 |
| Coil Voltage | 24VAC |