We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
lovato sm1r1800 sm1 rotary control motor circuit breaker 13 - 18 amp
MPN: SM1R1800
Why Choose the SM1R1800?
The Lovato SM1R1800 motor protection circuit breaker delivers reliable protection for three‑phase motors with a 13–18 A thermal trip adjustment range and 18 A rated current. With a formidable 100 kA Icu at 400 V and magnetic and thermal protection, it safeguards against overloads and short circuits. A rotary knob provides clear, simple control, while the compact 3‑pole design integrates neatly into control panels.
Engineered for demanding environments, the SM1R range offers 690 V Ui and 6 kV Uimp, a mechanical life of 100,000 cycles, and dependable operation from −20 to +60 °C up to 3000 m altitude. Terminals tighten to 2.5–3 Nm for secure connections. Conforms to IEC/EN 60947-1/-2/-4-1, UL508 and CSA C22.2 n° 14, with a Sustainability certification to support responsible specification.
Key Benefits
- High 100 kA Icu at 400 V for strong short‑circuit protection.
- Adjustable 13–18 A thermal range suits varied motor loads.
- Combined magnetic and thermal protection enhances reliability.
- 3‑pole design ideal for three‑phase motor circuits.
- Rotary control knob enables quick, intuitive setting and reset.
- Robust 690 V insulation and 6 kV impulse withstand.
- Wide −20 to +60 °C operating temperature for harsh sites.
Technical Specification
- Product type designation: SM1R
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Mechanical life: 100000 cycles
- Terminal tightening torque: 2.5 to 3 Nm
- Operating temperature: -20 to +60 °C
- Storage temperature: -50 to +80 °C
- Max altitude: 3000 m
- Weight: 390 g
What’s Included
- Lovato SM1R1800 motor protection circuit breaker unit
- Installation and safety instructions
Applications
- Protection of three‑phase motors within the 13–18 A setting range.
- Control panels requiring IEC/EN 60947 compliant motor protection.
- Installations needing 100 kA breaking capacity at 400 V.
- Sites operating between −20 and +60 °C up to 3000 m altitude.
Frequently Asked Questions
What current range can the SM1R1800 be set to?
What is its short‑circuit breaking capacity at 400 V?
What protection functions and control does it provide?
Which standards does this breaker conform to?
Is it UL Type E certified?
Safety note: Installation must be performed by qualified personnel. Isolate the supply before work, tighten terminals to 2.5–3 Nm, and observe the stated operating limits and standards.
| Manufacturer Part Number | SM1R1800 |
|---|---|
| Barcode | 8013975216378 |
| HS Code | 85362010 |
| Manufacturer | Lovato |