We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
lovato sm1r1400 sm1 rotary control motor circuit breaker 9 - 14 amp
MPN: SM1R1400
Why Choose the SM1R1400?
Engineered by Lovato, the SM1R1400 motor protection circuit breaker safeguards three‑phase motors with dependable magnetic and thermal protection. With an adjustable 9...14 A thermal trip and a robust 100 kA Icu at 400 V, it delivers fast fault clearing and precise overload control. A 3‑pole format and intuitive rotary knob simplify setup and on‑site adjustments for consistent, repeatable protection.
Built for demanding installations, SM1R series performance includes Ui 690 V and Uimp 6 kV, with reliable operation from -20 to +60 °C up to 3000 m altitude. Tested for 100000 mechanical cycles and compliant with IEC/EN 60947-1, 60947-2 and 60947-4-1, plus UL508 and CSA C22.2 n° 14. Terminal tightening torque is 2.5 to 3 Nm for secure connections.
Key Benefits
- High short-circuit breaking capacity: Icu 100kA at 400V.
- Adjustable thermal trip from 9 to 14 A for precise protection.
- Combined magnetic and thermal protection in one compact unit.
- Simple, reliable rotary knob control for on-site setting.
- Rated insulation voltage Ui 690 V for robust system resilience.
- Withstands 6 kV impulse overvoltage; suitable up to 3000 m altitude.
- Wide operating temperature range from -20 to +60 °C.
Technical Specification
- Product type designation: SM1R
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Mechanical life: 100000 cycles
- Terminal tightening torque: 2.5 to 3 Nm
- Operating temperature: -20 to +60 °C
- Storage temperature: -50 to +80 °C
- Max altitude: 3000 m
- Weight: 390 g
What’s Included
- Lovato SM1R1400 motor protection circuit breaker (3‑pole)
- Manufacturer product datasheet (downloadable)
- Protective packaging for transit
Applications
- Protection and control of three-phase motor circuits within 9...14 A.
- IEC/EN 60947-compliant motor starter assemblies and control panels.
- Installations requiring 100 kA Icu at 400 V short-circuit capability.
- Environments operating between -20 and +60 °C, up to 3000 m altitude.
Frequently Asked Questions
What is the adjustable thermal trip range?
What short-circuit breaking capacity does it provide at 400 V?
How many poles and what control type does it have?
Which standards does the SM1R1400 conform to?
What are the environmental and endurance ratings?
Safety note: Install and commission only by qualified personnel. Isolate power before work, tighten terminals to 2.5–3 Nm, and follow IEC/EN 60947 practices and local regulations.
| Manufacturer Part Number | SM1R1400 |
|---|---|
| Barcode | 8013975216361 |
| HS Code | 85362010 |
| Manufacturer | Lovato |