We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
lovato sm1r0650 sm1 rotary control motor circuit breaker 4 - 6.5 amp
MPN: SM1R0650
Why Choose the SM1R0650?
Designed for dependable motor protection, the Lovato SM1R0650 motor protection circuit breaker (Type E) delivers high fault withstand with IEC Icu 100kA at 400V. Its adjustable 4…6.5 A thermal trip and combined magnetic and thermal protection guard motors against overloads and short circuits. A positive rotary knob offers clear local control, while the 3‑pole SM1R platform supports coordinated motor starting in control panels.
Built for tough environments, this breaker offers Ui 690 V and 6 kV impulse withstand, with a mechanical life of 100000 cycles. It operates from -20 to +60 °C up to 3000 m altitude, with terminal tightening torque 2.5 to 3 Nm and 390 g weight. Conforms to IEC/EN 60947-1/-2/-4-1, UL508 and CSA C22.2 n° 14, and is certified UL Type E.
Key Benefits
- High IEC Icu 100kA at 400V for strong short-circuit protection.
- Adjustable thermal trip 4…6.5 A to match motor full-load current.
- Combined magnetic and thermal protection for overloads and faults.
- Rotary knob control for straightforward local operation.
- 3‑pole SM1R design suited to three-phase motor circuits.
- Rated insulation 690 V with 6 kV impulse withstand capability.
- UL Type E and IEC/EN 60947 conformity for assured compliance.
Technical Specification
- Product type designation: SM1R
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Mechanical life: 100000 cycles
- Terminal tightening torque: 2.5 to 3 Nm
- Operating temperature: -20 to +60 °C
- Storage temperature: -50 to +80 °C
- Max altitude: 3000 m
- Weight: 390 g
What’s Included
- Lovato SM1R0650 motor protection circuit breaker (3‑pole)
- Manufacturer documentation (datasheet/user information)
- Original manufacturer packaging
Applications
- Three‑phase motor protection in industrial control panels
- Pump, fan and compressor motor circuits
- Conveyors and material handling motors
- Machine tools and process line equipment
- HVAC motor starter assemblies
Frequently Asked Questions
What is the adjustable thermal trip range of the SM1R0650?
What short-circuit breaking capacity does it have at 400 V AC?
Is the SM1R0650 UL Type E certified?
Which standards does this breaker conform to?
What are the operating temperature and altitude ratings?
Safety note: Install and set by qualified personnel only. Isolate power before work, tighten terminals to 2.5–3 Nm, and set the 4…6.5 A trip to the motor’s rated current in accordance with applicable standards.
| Manufacturer Part Number | SM1R0650 |
|---|---|
| Barcode | 8013975216347 |
| Manufacturer | Lovato |