Lovato GLC0400C1 IEC/EN three-pole changeover switch 400A
MPN: GLC0400C1
Alt. SKU: GLC0400 C1
Why Choose the GLC0400C1?
The Lovato GLC0400C1 is a three-pole changeover switch designed for dependable AC source transfer in high-current systems. With an IEC conventional free air thermal current Ith of 400 A, rated insulation voltage Ui of 1000 V and impulse withstand Uimp of 12 kV, it suits demanding requirements. The GLC series device installs via screw-on plate and complies with IEC/EN 60947 standards, supporting reliable switching performance and straightforward integration in compliant assemblies.
High making and breaking capacities at 400 V (4000 A/3200 A) enable secure transfer under load, while AC-23A ratings deliver up to 200 kW at 400 V and 400 kW at 690 V. A conditional short-circuit current of 80 kA with gG/400 fuse, 10,000-cycle mechanical life, -25 to +55 °C operation and up to 3000 m altitude underline durability. Terminals accept 30 to 37 Nm torque for firm, safe connections.
Key Benefits
- 400 A Ith ensures dependable performance on high-current three-phase AC systems.
- AC-23A power: 200 kW at 400 V, 400 kW at 690 V.
- Rated Ui 1000 V and Uimp 12 kV for insulation and surge robustness.
- Strong making/breaking at 400 V: 4000 A and 3200 A under load.
- Conditional short-circuit rating 80 kA when protected by gG/400 fuse.
- Operates -25 to +55 °C and up to 3000 m altitude.
- Durable 10,000-cycle mechanical life supports long-term reliability.
- Screw-on plate mounting and 30 to 37 Nm terminal torque security.
Technical Specification
- Product type designation: GLC
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 400 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 12 kV
- Power dissipation per pole (max): 26.0 W
- Rated operational power AC23A 400 V: 200 kW
- Rated operational power AC23A 690 V: 400 kW
- Conditional short-circuit current (rms): 80 kA
- Short-circuit protection fuse: gG/400
- Making capacity AC23A 400 V: 4000 A
- Breaking capacity AC23A 400 V: 3200 A
- Mechanical life: 10000 cycles
- Terminal tightening torque: 30 to 37 Nm
- Operating temperature: -25 to +55 °C
- Storage temperature: -40 to +70 °C
- Max altitude: 3000 m
What’s Included
- Lovato GLC0400C1 three-pole changeover switch
- Manufacturer technical datasheet
- Basic installation and safety information
- Protective packaging
Applications
- Mains to generator changeover in three-phase AC installations
- Source selection and load transfer in power distribution panels
- Switching of AC-23A category motor and mixed resistive/inductive loads
- Maintenance bypass and system isolation during service operations
Frequently Asked Questions
What standards does the GLC0400C1 comply with?
How many poles does it have and what is the operating voltage type?
What are the AC-23A power ratings?
What short-circuit protection is required?
What are the operating limits for temperature and altitude?
Safety note: Installation and commissioning must be performed by qualified personnel. Isolate all power sources before work, observe IEC/EN 60947 requirements, use the specified gG/400 fuse, and tighten terminals to 30 to 37 Nm.
| Manufacturer Part Number | GLC0400C1 |
|---|---|
| Barcode | 8013975267141 |
| HS Code | 85365080 |
| Manufacturer | Lovato |
| Number of Poles | 3 Pole |
| Amperage | 400A |
| Alternative Product SKU | GLC0400 C1 |