Lovato GL0315C1 IEC/EN three-pole switch disconnector 315A
MPN: GL0315C1
Why Choose the GL0315C1?
Engineered for reliable isolation, the Lovato GL0315C1 three-pole switch disconnector (SKU GL0315C1) delivers 315 A IEC Ith for AC systems with Ui 1000 V and Uimp 12 kV. Designed for straightforward panel integration, it mounts by screws on plate or on a 35 mm DIN rail, providing a robust isolator for power distribution and control assemblies, and conforms to IEC/EN 60947-3 and 60947-1.
High utilisation category performance includes Ie 315 A for AC21A/AC22A, and AC23A 315 A at 400 V, 250 A at 500-690 V, and 135 A at 1000 V. It offers 2,500 A making and 2,000 A breaking capacity, 100 kA conditional short-circuit rating (gG/315 fuse), 20,000-cycle mechanical life, and secure terminations for 70 to 185 mm² conductors at 15 to 22 Nm.
Key Benefits
- Three-pole AC isolation with 315 A IEC free air rating.
- Wide operating range: Ui 1000 V and 12 kV impulse withstand.
- Flexible mounting on plate or 35 mm DIN rail.
- High conditional short-circuit capability of 100 kA with gG/315 fuse.
- Strong making 2,500 A and breaking 2,000 A at AC23A 400 V.
- Long service life with 20,000 mechanical cycles.
- Accepts 70 to 185 mm² conductors; 15 to 22 Nm terminal torque.
- Operates from -25 to +55 °C; performance up to 3000 m altitude.
Technical Specification
- Product type designation: GL
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 315 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 12 kV
- Operating current Ie AC21A 400 V: 315 A
- Operating current Ie AC21A 500 V: 315 A
- Operating current Ie AC21A 690 V: 315 A
- Operating current Ie AC21A 1000 V: 315 A
- Operating current Ie AC22A 400 V: 315 A
- Operating current Ie AC22A 500 V: 315 A
- Operating current Ie AC22A 690 V: 315 A
- Operating current Ie AC23A 400 V: 315 A
- Operating current Ie AC23A 500 V: 250 A
- Operating current Ie AC23A 690 V: 250 A
- Operating current Ie AC23A 1000 V: 135 A
- Power dissipation per pole (max): 6.5 W
- Rated operational power AC23A 400 V: 140 kW
- Rated operational power AC23A 690 V: 250 kW
- Conditional short-circuit current (rms): 100 kA
- Short-circuit protection fuse: gG/315
- Making capacity AC23A 400 V: 2500 A
- Breaking capacity AC23A 400 V: 2000 A
- Mechanical life: 20000 cycles
- Terminal tightening torque: 15 to 22 Nm
- Conductor section (IEC): 70 to 185 mm²
- Operating temperature: -25 to +55 °C
- Storage temperature: -40 to +70 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato GL0315C1 switch disconnector
- Mounting documentation and installation guide
- Manufacturer technical datasheet
Applications
- Main isolation for industrial AC circuits up to 315 A
- Panel and switchboard incomer or outgoing circuit disconnection
- Motor and load isolation in power distribution and control panels
- DIN rail assemblies requiring compact three-pole switching
Frequently Asked Questions
Is the GL0315C1 suitable for DIN rail mounting?
What are the AC23A current ratings?
What is the maximum rated insulation voltage?
What conductor sizes and torque are required?
What short-circuit protection should be used?
Safety note: Installation must be performed by qualified personnel. Always isolate the supply, verify absence of voltage, use the specified gG/315 fuse, and tighten terminals to 15–22 Nm within the stated environmental limits.
| Manufacturer Part Number | GL0315C1 |
|---|---|
| Barcode | 8013975228630 |
| HS Code | 85365080 |
| Manufacturer | Lovato |
| Number of Poles | 3 Pole |
| Amperage | 315A |