Do you need some help?

Call us now on: 01706 242050

K2-2P275-M Mersen Surge Protector Type 2 SPD 2 Pole 230 Volt 20KA TNS Remote Indication

MPN: 44020203

Alt. SKU: K2-2P275-M

Special Price £72.29 £60.24 Regular Price £96.38

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

This product replaces this item:

Free delivery on orders over £200

Why Choose the IR K2-2P275-M SPD?

The IR K2-2P275-M is a reliable Type 2, two-pole surge protection device designed for use in low-voltage AC distribution systems. With a continuous operating voltage (Uc) of 275Vac, it effectively safeguards sensitive equipment from transient overvoltages and lightning-induced surges.

Engineered for straightforward DIN rail mounting, this SPD is ideal for industrial and commercial installations requiring robust surge protection. Its durable construction ensures long-term performance, supporting system safety and minimising costly downtime.

Product Code: 44020203

Key Benefits

  • Effective protection against transient overvoltages and lightning surges.
  • Easy DIN rail mounting for quick and secure installation.
  • Durable housing materials (PA6 CT1 & PA66 CT1) ensure long service life.
  • Visual and microswitch indication system for status monitoring.
  • High nominal discharge current (20 kA) and maximum discharge current (50 kA) for robust surge handling.
  • Compatible with TNS system configurations.

Compatibility

The IR K2-2P275-M SPD is compatible with low-voltage AC distribution systems operating at 230V nominal voltage, specifically designed for TNS system configurations. It supports protection modes L-PE and N-PE and can be integrated with systems requiring a maximum back-up fuse rating of 315 A [gG].

Applications

  • Industrial and commercial electrical distribution panels.
  • Protection of sensitive electronic equipment from surge damage.
  • Installation in power line surge protection systems.
  • Use in environments requiring DIN rail mounted surge protection devices.
  • Systems needing compliance with IEC Class II and UL Type 1 Component Assembly standards.

Technical Specifications

  • Item number: 44020203
  • Catalogue No: K2-2P275-M
  • Description: SPD, T2, 2P, Uc 275Vac, IR
  • EAN/UPC Code: 8435297889786
  • RoHS Compliant: Yes
  • IEC SPD Type: Class II
  • UL SPD Type: Type 1 Component Assembly
  • Format: Pluggable
  • Nominal Operating Volt Rating (Un): 230
  • AC or DC: AC
  • Nominal Discharge Current (In) (8/20): 20 kA
  • Max Discharge Current : Imax (8/20): 50 kA
  • Protection Modes: L-PE / N-PE
  • System Configuration: TNS
  • Short Circuit Withstand (ISCCR): 25 kA
  • Indication System: Yes
  • Indication System Type: Green (OK) / Not green (replace) Microswitch
  • Number of Poles: 2-Pole
  • Torque Rating: 3 Nm
  • Max. Back-Up Fuse: 315 A [gG]
  • Housing Material: PA6 CT1 & PA66 CT1
  • MOV Response Time: ≤25
  • Installation Mounting: DIN rail
  • MCOV L-G: 275 V
  • MCOV N-G: 275 V
  • MCOV L-N: 550 V
  • VPR L-G: 1000 V
  • VPR N-G: 1000 V
  • VPR L-N: 1800 V
  • Replacement Plug L1: 44020001
  • Product Width: 36 mm
  • Product Length: 74.4 mm
  • Product Height: 90 mm
  • Sell Pack Quantity: 1 EA
  • Sell Pack Weight: 0.272 kg
  • Sell Pack Width: 38 mm
  • Sell Pack Length: 97 mm
  • Sell Pack Height: 118 mm
  • Product group: Power Line SPDs
  • Product Weight: 0.242 kg

Frequently Asked Questions

What is the maximum continuous operating voltage of the IR K2-2P275-M?

The maximum continuous operating voltage (Uc) of the IR K2-2P275-M is 275 Vac.

Can this SPD be mounted on a DIN rail?

Yes, the IR K2-2P275-M is designed for easy DIN rail mounting.

What type of indication system does this SPD have?

It features a green (OK) / not green (replace) microswitch indication system for status monitoring.

What is the nominal discharge current rating?

The nominal discharge current (In) is 20 kA (8/20 µs waveform).

Is the IR K2-2P275-M RoHS compliant?

Yes, this product is RoHS compliant.

Common Search Terms

surge protection device, SPD, Type 2 SPD, two-pole surge protector, DIN rail SPD, low voltage surge protector, 275Vac SPD, industrial surge protection, power line SPD, transient voltage suppressor

More Information
Manufacturer Part Number 44020203
Packed Quantity 1
Barcode 8435297889786
Height 74.4mm
Width 36mm
Depth 90mm
HS Code 85363090
Country of Manufacture Spain
Manufacturer Mersen
Number of Poles 2 Pole
Voltage 230V
Maximum Continuous Voltage 275V
Nominal Discharge Current 20Ka
Remote Indication Yes
Alternative Product SKU K2-2P275-M